Answers are grounded in this paper and cite their sources.
Package-integrated matching networks (MNs) are widely used in RF GaN HEMTs; however, it remains unclear whether human body model (HBM) and transmission line pulse (TLP) stresses produce distinguishable degradation in devices with MNs. This work investigates repetitive gate-ESD-induced pinch-off voltage (Vth) degradation in packaged RF GaN HEMTs with and without MNs under HBM and TLP stress. Under positive HBM and TLP stress, the Schottky gate is forward-biased, and high current density at the Schottky interface causes damage and Vth degradation. Because the DUT resistance is much smaller than the stress source resistance, the MN has a negligible effect on the gate voltage, and the Vth degradation trends are similar for DUTs with and without MN. Under negative HBM stress, the reverse-blocked Schottky gate and high electric field at the gate edge induce defects and Vth degradation. The MN can suppress the gate voltage and alleviate degradation in the DUT with an MN. The difference becomes more pronounced as the negative HBM voltage increases. In contrast, under negative TLP stress, the standardized 50 Ω source impedance keeps the gate-voltage difference small, so no obvious Vth degradation difference is observed between DUTs with and without MN. Simplified analytical models and TCAD simulations consistently explain these trends, clarifying why RF GaN HEMTs with an MN and without an MN exhibit distinguishable Vth degradation under negative HBM stress but not under negative TLP stress.
No takes yet. Share an insight, caveat, or question.
Ye et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: