The optimal systolic blood pressure target after recanalization in acute ischemic stroke is unknown, as earlier trials and meta-analyses contrasted intensive lowering with usual care rather than defined targets.
Comparison
Five systolic blood pressure targets (<120, <130, <140, <160 and <180 mmHg)
Design
Systematic review and Bayesian random-effects network meta-analysis of randomized controlled trials
Follow-up
90 days
Answers are grounded in this paper and cite their sources.
Intensive post-reperfusion systolic blood pressure targets do not improve 90-day independence; low-certainty evidence leaves optimal target unresolved.
Background Reperfusion therapy improves outcomes in acute ischemic stroke (AIS), but the optimal systolic blood pressure (SBP) target after recanalization is unknown. Earlier trials and meta-analyses contrasted intensive lowering with usual care rather than defined targets. We compared five SBP targets across populations treated with thrombolysis or thrombectomy. Methods We searched four databases from inception to 2 August 2026 and two trial registers without date restriction for randomized trials of reperfusion-treated AIS with a defined SBP target. Bayesian random-effects consistency models compared five targets (<120, <130, <140, <160 and <180 mmHg), with <180 mmHg as the reference. Primary outcomes were 90-day functional independence (modified Rankin Scale 0–2) and all-cause death; secondary outcomes were symptomatic and any intracerebral hemorrhage. Certainty was graded with CINeMA, and exploratory network meta-regression used mean age, reperfusion modality and baseline NIHSS. Results Ten trials randomized 4,790 patients, of whom 4,710 entered the functional-outcome network (mean age 69.5 years). For functional independence, all ten pairwise comparisons had 95% credible intervals spanning 1, so no target showed a credible advantage. Against <180 mmHg, relative risks were 0.78 (95% CrI 0.53 to 1.13) for <120, 0.94 (0.65 to 1.35) for <130, 1.01 (0.80 to 1.28) for <140 and 0.93 (0.67 to 1.28) for <160. For <120 mmHg the estimate was furthest from unity: the interval excluded an important benefit but included an important harm. All-cause death rose across intensive targets (1.06, 1.20, 1.27 and 1.84) with wide intervals. For either hemorrhage outcome the credible intervals included 1, so no difference was detected, and meta-regression did not detect effect modification. No comparison reached high certainty with CINeMA; 3 were moderate, 21 low and 16 very low. Conclusion No uniformly lowered SBP target outperformed maintenance below 180 mmHg, although this does not establish 180 mmHg as optimal. The most aggressive target carried a signal of possible functional harm, but low certainty limits any claim that lower targets are harmful. Maintenance below 180 mmHg remains the best-supported default, and targets individualized by recanalization grade warrant priority testing. Systematic review registration https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD420261484481, identifer CRD420261484481.
No takes yet. Share an insight, caveat, or question.
Sun et al. (2026) studied this question.