Key result
Valve-preserving hemiarch replacement successfully manages rare type A aortic dissection 5 years post-SAPIEN 3 TAVI.
Why the study?
Late Stanford type A aortic dissection after balloon-expandable transcatheter aortic valve implantation is rare.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
This case report highlights a rare occurrence of late Stanford type A aortic dissection with a surgically confirmed frame-adjacent proximal tear 5 years after balloon-expandable SAPIEN 3 valve implantation, successfully treated with valve-preserving hemiarch replacement.
Late Stanford type A aortic dissection after balloon-expandable transcatheter aortic valve implantation is rare. An 89-year-old woman developed type A dissection 5years after uneventful SAPIEN 3 implantation. Intraoperatively, a large spiral entry tear began immediately above the noncoronary cusp-side stent edge. Because valve function was preserved and the annulus and root were intact, valve-preserving hemiarch replacement was performed. Although causality cannot be established, this case highlights a rare late aortic event with a surgically confirmed frame-adjacent proximal tear after balloon-expandable valve implantation.
No takes yet. Share an insight, caveat, or question.
Asada et al. (2026) conducted a case report in Late Stanford type A aortic dissection post-TAVI (n=1). Balloon-expandable SAPIEN 3 TAVI / Valve-preserving hemiarch replacement was evaluated on Late Stanford type A aortic dissection. Balloon-expandable SAPIEN 3 TAVI was followed 5 years later by a rare type A aortic dissection in an 89-year-old woman, managed with valve-preserving hemiarch replacement.
Synapse has enriched 10 related papers. Consider them for comparative context: