Highlights the rare but severe complication of type A aortic dissection occurring late after aortic valve replacement even when the ascending aorta was initially normal.
Answers are grounded in this paper and cite their sources.
Alerts clinicians to rare late dissection after AVR with normal initial aorta; hypothesis-generating for post-AVR surveillance.
Type A aortic dissection occurs in 0.6% of patients late after aortic valve replacement. However, little information is available about risk factors for developing this complication, nor are recommendations for elective replacement of the ascending aorta available. The authors present a 78-year-old woman who developed type A aortic dissection thirty months after aortic valve replacement; ascending aorta was normal at the time of aortic valve replacement.
No takes yet. Share an insight, caveat, or question.
Picchi et al. (2003) studied this question.