Why the study?
AF may reduce cardiac output through several possible mechanisms, and this study was designed to isolate the hemodynamic effects of an irregular RR interval sequence independently of average ventricular rate.
Does an irregular sequence of ventricular cycle lengths (RR intervals) independently impair cardiac hemodynamics compared with regular pacing at the same average heart rate in patients with atrial fibrillation?
Does an irregular sequence of ventricular cycle lengths (RR intervals) independently impair cardiac hemodynamics compared with regular pacing at the same average heart rate in patients with atrial fibrillation?
Demonstrates that the irregularity of ventricular contraction in atrial fibrillation independently reduces cardiac output and increases cardiac filling pressures, even when average heart rate is controlled.
Answers are grounded in this paper and cite their sources.
Irregular ventricular response impairs hemodynamics independent of rate; challenges rate control alone as optimal for AF.
Objectives The aim of this study was to determine the independent hemodynamic effects of an irregular sequence of ventricular cycle lengths in patients with atrial fibrillation (AF). Background Atrial fibrillation may reduce cardiac output by several possible mechanisms, including loss of the atrial contribution to left ventricular filling, valvular regurgitation, increased ventricular rate or irregular RR intervals. This study was designed to evaluate the effects of an irregular RR interval, independent of the average ventricular rate, on cardiac hemodynamic data during AF. Methods Sixteen patients with AF were studied invasively. During intrinsically conducted AF (mean rate 102 +/- 22 beats/ min), the right ventricular apex electrogram was recorded onto frequency-modulated (FM) tape. After atrioventricular node ablation, the right ventricular apex was stimulated in three pacing modes in randomized sequence: 1) VVI at 60 beats/min; 2) VVI at the same average rate as during intrinsically conducted AF (102 +/- 22 beats/min); and 3) during VVT pacing in which the pacemaker was triggered by playback of the FM tape recording of the right ventricular apex electrogram previously recorded during intrinsically conducted AF (VVT 102 +/- 22 beats/min). Results Compared with VVI pacing at the same average rate, an irregular sequence of RR intervals decreased cardiac output (4.4 +/- 1.6 vs. 5.2 +/- 2.4 liters/min, p < 0.01), increased pulmonary capillary wedge pressure (17 +/- 7 vs. 14 +/- 6 mm Hg, p < 0.002) and increased right atrial pressure (10 +/- 6 vs. 8 +/- 4 mm Hg, p < 0.05). Conclusions An irregular sequence of RR intervals produces adverse hemodynamic consequences that are independent of heart rate.
No takes yet. Share an insight, caveat, or question.
Clark et al. (1997) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: