Key result
Proximal LCx ischemia impairs LA pump function, whereas distal LAD ischemia augments it.
Why the study?
Compensatory augmentation of LA contraction enhances LV filling during LV ischemia, and because the LA is supplied predominantly by branches of the LCx, ischemic LA dysfunction was hypothesized as a mechanism for loss of atrial contraction.
Does pacing-induced or balloon coronary occlusion ischemia in patients with proximal LCx stenosis impair left atrial pump function compared to patients with distal LAD stenosis?
Observational (n=32)
Does pacing-induced or balloon coronary occlusion ischemia in patients with proximal LCx stenosis impair left atrial pump function compared to patients with distal LAD stenosis?
Unlike distal LAD ischemia which induces compensatory augmentation of left atrial pump function, proximal LCx ischemia impairs left atrial booster pump function, likely due to direct ischemia of left atrial branches.
Answers are grounded in this paper and cite their sources.
Ischemia impairs LA pump function in CAD; leaves open whether LA mechanics aid procedural risk stratification.
Objectives The aim of this study was to compare left atrial (LA) function in 16 patients with distal left anterior descending (LAD) and in 16 patients with proximal left circumflex (LCx) coronary artery stenosis at rest and immediately after pacing-induced tachycardia (LAD-pacing [P] and LCx-P) or coronary occlusion (LAD-CO and LCx-CO). Background During left ventricular (LV) ischemia, compensatory augmentation of LA contraction enhances LV filling and performance. The left atrium is supplied predominantly by branches arising from the LCx. Therefore, we hypothesized that one mechanism for the loss of atrial contraction may be ischemic LA dysfunction. Methods Left ventricular and LA pressure-area relations were derived from simultaneous double-tip micromanometer pressure recordings and automatic boundary detection echocardiograms. Results Immediately after pacing or after coronary occlusion, LV end-diastolic pressure, LV relaxation, LA mean pressure and LV stiffness significantly increased in all patients. However, the area of the A loop of the LA pressure-area relation, representing the LA pump function, significantly decreased in groups LCx-P and LCx-CO (from 14+/-3 to 9+/-2, and from 16+/-4 to 9+/-2 mm Hg.cm2, respectively, p < 0.05), whereas it increased in groups LAD-P and LAD-CO (from 12+/-3 to 54+/-10, and from 16+/-3 to 49+/-8 mm Hg.cm2, respectively, p < 0.001). Conclusions In patients with LAD stenosis, LV supply or demand ischemia is associated with enhanced LA pump function. However, in patients with proximal LCx stenosis who develop the same type and degree of ischemia, LA branches might have been affected, rendering the LA ischemic and unable to increase its booster pump function.
No takes yet. Share an insight, caveat, or question.
Stefanadis et al. (1999) conducted an observational in Coronary artery disease (distal LAD or proximal LCx stenosis) (n=32). Pacing-induced tachycardia and balloon coronary occlusion in proximal LCx stenosis vs. Pacing-induced tachycardia and balloon coronary occlusion in distal LAD stenosis was evaluated on Left atrial pump function (area of the A loop of the LA pressure-area relation) (p=<0.05). Ischemia in proximal LCx stenosis decreased LA A-loop area, whereas ischemia in distal LAD stenosis increased it.
Synapse has enriched 10 related papers. Consider them for comparative context: