Key result
CRT-ICD improves quality of life quality of life measures over ICD alone, driven by patients with LBBB.
Why the study?
CRT with an ICD reduces heart failure risk among minimally symptomatic patients, but whether this improves quality of life was unknown.
Does cardiac resynchronization therapy with an implantable cardioverter-defibrillator (CRT-ICD) improve quality of life compared to an ICD only in patients with minimally symptomatic heart failure, reduced ejection fraction, and prolonged QRS duration?
RCT (n=1,699)
Yes
Does cardiac resynchronization therapy with an implantable cardioverter-defibrillator (CRT-ICD) improve quality of life compared to an ICD only in patients with minimally symptomatic heart failure, reduced ejection fraction, and prolonged QRS duration?
CRT-ICD significantly improves quality of life compared to ICD alone in minimally symptomatic heart failure patients with reduced ejection fraction, specifically among those with left bundle branch block.
Answers are grounded in this paper and cite their sources.
Should not yet change CRT practice in minimally symptomatic HF; leaves open QoL benefits for randomized confirmation.
OBJECTIVES: This study compared the quality of life (QOL) of patients with cardiac resynchronization therapy (CRT) and an implantable cardioverter-defibrillator (ICD) to patients with an ICD only. BACKGROUND: CRT with ICD is associated with a reduction in heart failure risk among minimally symptomatic patients. It is unknown whether this improves QOL. METHODS: This study uses the MADIT-CRT (Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy) data. The MADIT-CRT enrolled 1,820 patients at 110 centers across 14 countries. Patients had ischemic cardiomyopathy (New York Heart Association [NYHA] functional class I or II) or nonischemic cardiomyopathy (NYHA functional class II only), sinus rhythm, an ejection fraction of 30% or less, and prolonged intraventricular conduction with a QRS duration of 130 ms or more. QOL was evaluated on the 1,699 patients with baseline and follow-up measures using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Six dimensions (Physical Limitation, Symptom Stability, Symptom Frequency, Symptom Burden, Quality of Life, and Social Limitations) and 3 summary scores (Total Symptom, Clinical Summary, and Overall Summary) were analyzed. RESULTS: During an average follow-up of 2.4 years, the CRT-ICD group had greater improvement than the ICD-only group on all KCCQ measures (p < 0.05 on each scale). These differences were significant among patients with left bundle branch block conduction disturbance (n = 1,204, p < 0.01 on each scale), but not among patients without left bundle branch block (n = 494). CONCLUSIONS: Compared with patients with ICD only, CRT-ICD is associated with greater improvement in QOL among relatively asymptomatic patients, specifically among those with left bundle branch conduction disturbance.
No takes yet. Share an insight, caveat, or question.
Veazie et al. (2012) conducted an RCT in Minimally symptomatic heart failure (ischemic cardiomyopathy NYHA class I or II, or nonischemic cardiomyopathy NYHA class II) (n=1,699). Cardiac resynchronization therapy with implantable cardioverter-defibrillator (CRT-ICD) vs. Implantable cardioverter-defibrillator (ICD) only was evaluated on Quality of life measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ) across 6 dimensions and 3 summary scores (p=<0.05). CRT-ICD improved quality of life on all quality of life measures compared with ICD only, driven by patients with LBBB.
Synapse has enriched 10 related papers. Consider them for comparative context: