Answers are grounded in this paper and cite their sources.
This research paper had the objective of evaluating the accuracy of an experimental chromogenic medium for detection of Streptococcus agalactiae intramammary infection, using quarter and composite milk samples. Four herds were visited once to collect milk samples from all lactating cows (N = 117). Quarter and composite samples were plated on the chromogenic medium (index test). Simultaneously, quarter samples were plated on blood agar, and the catalase-negative cocci isolates were further speciated by MALDI-TOF MS (reference standard). Three thresholds were used to estimate the chromogenic medium's accuracy parameters. The coefficient of agreement between observers was 0.71 for the final diagnosis of S. agalactiae, and 0.88 for determining colony colours. For quarter milk samples, sensitivity ranged from 44.35% to 87.54%, depending on the threshold. The specificity was 97.81% to 93.55%. The positive predictive value was 80.68% to 83.60%. The negative predictive value was 87.62% to 98.87%. For composite milk samples, there was little difference in accuracy compared to quarter milk samples. Accuracy was highly variable among farms. Regardless of the threshold used, the observed proportion of false-negative results may not be acceptable in S. agalactiae eradication programmes. The variability in accuracy among farms should be further studied under field conditions.
No takes yet. Share an insight, caveat, or question.
Juliano et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: