Answers are grounded in this paper and cite their sources.
This study looks at sustainable masonry mortars that use anhydrous calcium sulfate (ACS), a by-product of hydrofluoric acid production, as a partial replacement for cement and sand. Researchers tested five mixes with about 30% sand replaced and cement substituted at 0%, 10%, 30%, and 60%. The goal was to lower the environmental impact while keeping good structural performance. The performance of the mortar and masonry was evaluated by measuring consistency, workable life, flexural and compressive strengths, and initial shear strength under zero precompression to focus on the mortar’s effect. They tested prismatic samples and masonry triplets after 28 days of curing. The results showed that ACS significantly boosts mechanical performance. Flexural strength increased by up to 55%, and compressive strength reached 40 to 44 MPa, compared with about 22 MPa for the reference mortar. The initial shear strength of masonry went up by about 30%, mainly due to replacing 30% of the sand with ACS. Workable life improved by up to 80%, and consistency remained within acceptable limits for masonry. Replacing cement had little effect on strength, with sand substitution making the biggest difference. This study shows that ACS-based mortars are structurally sound. It also suggests there is a linear relationship between mortar compressive strength and masonry initial shear strength under no precompression, which holds true up to 50 MPa.
No takes yet. Share an insight, caveat, or question.
Stochino et al. (2026) studied this question.