This paper presents a rule-based criterion for the supervisory scheduling and design verification of Power-to-Hydrogen plants, extensible to other Power-to-X applications. Given a sized plant and an exogenous renewable profile, the method provides a transparent policy maximizing hydrogen delivery under explicit operability constraints. A compact logical sequence reduces each hourly decision to two degrees of freedom, solved through exhaustive grid search; feasibility is enforced by auditable if–then rules reflecting storage dynamics and process bounds. Industrial preferences ( e.g. , inventory-aware weighting, start-up/shutdown aversion) are incorporated via supplementary rules or lightweight penalties without altering the underlying logic. Applied to a previously sized 100-t NH3 /d green ammonia plant (requiring 6833 t H2 /y feedstock) over 8760 h, the inventory-aware policy delivers 6974 t H2 /y (+2.1%) with 1 h of downtime (performing ∼26 million objective function calls in less than 3 s), illustrating how design specifications can be verified within a simple, transparent, and computationally efficient supervisory framework.