Answers are grounded in this paper and cite their sources.
This study develops a multi-source diagnostic assessment of reduced moisture-transfer assumptions in hemp-lime materials. The evidence base combines numerical verification with HAMSTAD Benchmark 2, rear-face cyclic-RH responses from separate 70 and 120 mm specimens reconstructed from published hemp-lime data, an independent wall-scale thermal comparison, and a cross-literature plausibility assessment for hemp-lime and related bio-based materials. The finite-volume implementation reproduced the HAMSTAD reference solution, and a reduced dual-storage formulation improved the 7 cm cyclic-RH fit relative to the equilibrium formulation. However, the fitted hydric law did not transfer to the untouched 12 cm assessment, where the model transmitted excessive daily moisture variation. Conservation and discretisation checks address numerical error, while local fitting diagnostics and digitisation bands delimit the available evidence. They do not establish robustness to specimen variability or total experimental uncertainty. The independent thermal case supports the heat-transfer implementation but does not constitute hydric validation. Overall, the study identifies where the reduced moisture law is informative and where it loses transferability; it should be interpreted as a reproducible diagnostic assessment rather than a fully validated predictive law.
No takes yet. Share an insight, caveat, or question.
Berdai et al. (2026) studied this question.