Hydrogen permeation through polymer components presents a challenge for hydrogen transport, storage, and sealing. Hydrogen permeability of seven engineering polymer films, including polyolefins, a polyester, a polyamide, a polyether ketone, and two fluoropolymers, was measured at 5 bar over 20°C–80°C using a constant‐volume, variable‐pressure method. The apparatus, adapted from a commercial high‐pressure membrane filter holder, was verified against a certified air‐transmission reference film. Blank tests under hydrogen pressure at 22°C and 80°C showed a background below 0.2% of the permeation signal. Room‐temperature permeabilities spanned over an order of magnitude, from 1.4 × 10 −16 (poly(vinylidene fluoride)) to 3.9 × 10 −15 mol·m −1 ·Pa −1 ·s −1 (polytetrafluoroethylene). Crystallinity estimates from density and calorimetry were used to derive the amorphous‐phase permeability, which correlated approximately with the fractional free volume (R 2 ≈ 0.67). Polyamide 6,6 and poly(ethylene terephthalate) lay below the correlation whereas poly(ether ether ketone) and polytetrafluoroethylene fell above it. From 20°C to 80°C, the permeability followed Arrhenius behavior, with activation energies from 8.7 to 42.6 kJ/mol. Illustrative calculations for gas distribution pipelines and Type IV tank liners demonstrate possible applications of the data to permeation assessment; they use near‐ambient‐pressure measurements, address permeation only, and are not intended to provide design values.