Answers are grounded in this paper and cite their sources.
BACKGROUND: Dose escalation for locally advanced pancreatic cancer (LAPC) is challenging because of the proximity of gastrointestinal (GI) organs at risk. Carbon ion radiotherapy (CIRT) may offer dosimetric advantages, but the interfractional dose stability of a simultaneous integrated boost (SIB) to 75 Gy(RBE), with 67.5 Gy(RBE) prescribed to the remaining target volume in 15 fractions, remains insufficiently characterized. PURPOSE: To investigate the dosimetric feasibility of a simultaneous integrated boost (SIB) strategy in CIRT for LAPC and to evaluate interfractional dose stability using weekly verification CT datasets. METHODS: Sixteen LAPC patients previously treated with CIRT (67.5 Gy(RBE) in 15 fractions) were retrospectively analyzed. Two plans were generated for each case: a conventional plan (CPD) and a dose-escalated SIB plan (SIBPD) prescribing 75 Gy(RBE) to the integrated gross tumor volume (iGTV). Dose-averaged linear energy transfer (LETd) was additionally evaluated for the iGTV. Weekly four-dimensional CT (4DCT) scans were acquired, and dose was recalculated on 48 verification CT datasets to evaluate interfractional dosimetric stability using predefined target coverage and organ-at-risk (OAR) criteria. RESULTS: Compared with CPD, SIBPD achieved superior iGTV dose metrics, as expected from the higher boost prescription, while dose increases to gastrointestinal organs were of a smaller magnitude, with mean relative increases in near-maximum GI dose (D2cc) below 3%. SIBPD showed a higher LETd value covering 98% of the iGTV volume (L98), higher mean LETd (Lmean), and higher percentage of volume receiving LETd ≥44 keV/µm (V44), whereas minimum LETd (Lmin) was not significantly different. Criteria-exceedance classification on weekly verification CTs was identical between the two strategies (18/48 datasets each), and no statistically significant systematic increase in dose deterioration was observed with SIBPD. CONCLUSION: SIB-based CIRT to 75 Gy(RBE) in 15 fractions was dosimetrically feasible for LAPC. The higher prescribed target dose was achieved while maintaining GI OAR doses within predefined constraints, with no statistically significant systematic increase in interfractional dose deterioration compared with CPD.
No takes yet. Share an insight, caveat, or question.
Xing et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: