Growing electric vehicle (EV) adoption is intensifying feeder congestion in distribution grids, requiring control strategies that manage power line bottlenecks without compromising user transportation needs. Existing evaluation approaches rely on idealised simulations or costly, poorly repeatable field and hardware trials. This paper presents an offline, data-driven digital twin (DT) framework for EV charging clusters that bridges this gap via closed-loop controller testing. The DT combines site-specific charging behaviour, feeder power constraints and a distributed control architecture in a multi-controller-in-the-loop environment; it is modular enough to test alternative architectures. A workplace charging cluster (12 EVSEs) serves as a case study: the DT and accompanying parameters, validated on five measurement days and the same control logic, reproduces the aggregated feeder power with a root-mean-square error (RMSE) of 1.6 kW and a mean error of −0.3 kW while the 43 kW feeder limit binds. Over full days, the DT overestimates delivered energy by 8%, traced to EVs stopping or reducing charging before reaching their requested energy, information absent from the session data. The DT thus offers a reproducible intermediate layer between simplified simulation and field deployment for developing and testing congestion-management strategies.