Overview

Study compares utility-scale and distributed photovoltaic systems with battery energy-storage systems, suggesting optimal sizing affects outcomes.

Key Points

  • Imbalance netting and energy arbitrage improve financial returns for BESS with PV systems, enhancing market participation.
  • A utility-scale 1 MW PV system needs 220 kWh storage to maintain dispatchability, increasing costs by 13.1%.
  • A multistage stochastic mixed-integer linear programming model optimizes solar energy market offers, considering battery size.
  • Larger storage capacities yield better economic outcomes under a multiple-service strategy, indicating significant cost benefits.

Cite This Study

Scrocca et al. (2025) studied this question.