Key result
QRS vector algorithm misidentifies VT exit site in ~89% of scar-related ventricular tachycardias.
Why the study?
Does a vector-based QRS algorithm accurately predict the radiofrequency ablation termination site in scar-related ventricular tachycardia?
Observational (n=64)
Does a vector-based QRS algorithm accurately predict the radiofrequency ablation termination site in scar-related ventricular tachycardia?
Answers are grounded in this paper and cite their sources.
For scar-related VTs, the exit predicted from a vector-based QRS algorithm often differs from the actual ablation termination site, highlighting the limitations of relying solely on QRS morphology to guide ablation.
The QRS morphology of ventricular tachycardia (VT) reflects the re-entry circuit exit location and helps guide mapping for radiofrequency ablation (RFA). It can be misleading, however, particularly in structural heart disease. The aim of this study was to assess the relation of the site where RFA terminated VT to the location of the exit predicted by the VT QRS morphology. This study included 64 scar-related re-entrant left ventricular VTs (57.9% ischemic cardiomyopathy) with an identified region where RFA terminated the VT; a previously reported electrocardiogram algorithm that uses the QRS vector to predict the VT exit region on the American Heart Association 17-segment left ventricular model was applied. QRS discordant VTs were defined as having the RFA termination site outside of the predicted exit region. Entrainment and pace mapping (PM) data were also analyzed to assess possible reasons for discrepancies. The QRS morphology was discordant with the termination region in 57 (89%) VTs. Two types of discordance were seen. In 22 (34.4%), the termination region was remote from the circuit exit. In 32 (50%), the termination site was in the VT re-entry circuit exit, but the QRS suggested a different exit region. Analysis of voltage maps and PM suggested that the QRS vector was often altered by scar. For scar-related VTs, the exit predicted from a vector-based QRS algorithm often differs from the location where ablation terminates the VT. This is an important consideration for use of the QRS to guide VT ablation strategies. PM can potentially assist in recognizing this discrepancy and warrants study.
No takes yet. Share an insight, caveat, or question.
Katsume et al. (2025) conducted an observational in Scar-related ventricular tachycardia (n=64). Vector-based QRS algorithm was evaluated on QRS discordant VTs (RFA termination site outside of the predicted exit region). In 89% of scar-related ventricular tachycardias, the exit region predicted by a vector-based QRS algorithm was discordant with the actual site where radiofrequency ablation terminated the VT.