This analysis compares gate oxide performance in 4H-SiC and smartSiC wafers, revealing the RTA process impacts reliability.
In this work, a comparison of standard bulk 4H-SiC epi wafers and Soitec's SmartSiC™ wafers as well as the influence of RTA processing was conducted. For this, MOS capacitors were processed using thermal gate oxide paired with a polycrystalline gate electrode. Subsequent High temperature steps were avoided until an RTA process was performed on some of these wafers. To investigate the oxide quality on all wafer and process splits, CV-, time-zero dielectric breakdown and constant-current stress time-dependent dielectric breakdown measurements were carried out. For the examination of bulk wafers and SmartSiC™, no relevant differences in terms of yield, oxide quality, interface state density and reliability were found. In contrast, RTA processes seem to create a shift in flat band voltage and also lead to a reduction in oxide lifetime. The V FB shift could partially, but not completely, be explained by addition activation of dopants in the polysilicon electrode. The influence on the oxide reliability, however, is still unclear.