This research investigates the thermal performance of shaded roofs in the composite climate of Roorkee, India, by examining four shading materials (three opaque, one translucent) over an unobstructed roof for eight consecutive days. Using 'Designbuilder' software simulations and a mathematical model, the study meticulously triangulates experimental, simulated, and modelled data. The hourly temperature profile of the roof under different shades is analysed and the results showed negligible differences among opaque shading materials, while the translucent material significantly altered the roof's thermal performance due to solar transmittance. Opaque shades reduced peak heat gain through the roof by up to 77% and 71.5% on cloudy and sunny days, respectively, and reduced nighttime heat loss by 40% and 33%, respectively. This research underscores the importance of considering shading material properties in sustainable building design and confirms the reliability of simulation tools.
No takes yet. Share an insight, caveat, or question.
Sadevi et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: