Answers are grounded in this paper and cite their sources.
In this letter, we report an approach to improve the forward bias gate reliability of Schottky gate p-GaN HEMTs. In particular, a gate layout solution, namely Gate Within Active Area (GWA), aimed at improving the high-temperature time to failure (TTF), is proposed and validated. This solution allows to avoid the exposure of the gate finger (p-GaN/metal) to the nitrogen-implantation needed for termination and isolation purposes. GWA devices feature a significantly improved gate reliability at high temperature with respect to the reference ones, under both DC and pulsed stress tests. Finally, it is demonstrated that the Schottky gate p-GaN HEMTs show a positive temperature-dependent gate TTF in a range up to 150 °C, confirming the crucial role of impact ionization on the gate failure.
No takes yet. Share an insight, caveat, or question.
Tallarico et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: