This paper demonstrates a low-noise, offset and temperature coefficient (TC) bandgap reference for the portable biopotential signal monitoring system. The proposed feedback coefficient enhancement technique suppresses the low-frequency noise and offset voltage. Besides, the bowl-shaped curvature compensation is applied in the BGR to obtain a decent TC. The proposed bandgap reference was designed and fabricated by the <tex-math notation="LaTeX">0.18 ~μ m </tex-math> deep N-well CMOS technology with an active area of 0.088 mm2. Experimental results show that this BGR outputs 0.6 V reference voltage under 1.2 V supply voltage while consuming <tex-math notation="LaTeX">60 ~μ W </tex-math> power. The measured integrated noise from 0.1 to 10 Hz is about <tex-math notation="LaTeX">3.0 ~μ V </tex-math> (rms). In addition, the average TC of the BGR is 2.4 ppm /°C from −45 °C to 125 °C after trimming.
No takes yet. Share an insight, caveat, or question.
Liao et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: