A noncontact liquid-level sensor using a cylindrical coplanar waveguide (CCPW) is proposed. The concept is demonstrated using a prototype device made by directly spraying conductive paint on the outer surface of a glass cylinder. The position of the air–liquid interface is measured using the time-domain reflection (TDR) signal from the CCPW. The geometric parameters of the prototype sensor were optimized using a full-wave simulation tool. The experimental results show that the prototype CCPW-based liquid-level sensor has a resolution of <tex-math notation="LaTeX">29.8 μ m </tex-math> over a range of 210 mm at the sweeping frequency bandwidth of 500 MHz–4 GHz. The tradeoff between the resolution and the measurement range was discussed. The proposed sensor provides a low-cost, easy-to-fabricate, and noncontact method for liquid-level measurement, which has potential applications in fuel storage, chemical production, and wastewater treatment.
No takes yet. Share an insight, caveat, or question.
Jiao et al. (2024) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: