Answers are grounded in this paper and cite their sources.
Randomized controlled trial shows no difference in cobalt or chromium levels in total hip arthroplasty patients, indicating outcomes are similar for dual-mobility bearings.
Background: The primary purpose of this randomized controlled trial was to evaluate serum metal levels in patients after total hip arthroplasty (THA) with a conventional compared with a modular dual-mobility bearing. The secondary aim was to compare patient-reported outcome measure (PROM) scores between the 2 cohorts. Methods: Patients undergoing primary THA for osteoarthritis were randomized to receive either a modular dual-mobility or conventional polyethylene bearing. All patients received the same titanium acetabular and femoral components and a ceramic femoral head. Serum cobalt and chromium levels were measured preoperatively and annually at 1 through 5 years postoperatively. A total of 53 patients were enrolled. The 2 cohorts did not differ significantly in terms of demographics. In the conventional-bearing cohort, 76% of the patients were White and 24% were Black, African American; 48% of the patients were male and 52% were female. In the dual-mobility cohort, 86% of the patients were White and 14% were Black, African American; 79% of the patients were male and 21% were female. Results: Forty-one patients who were randomized to a modular dual-mobility (n = 24) or conventional (n = 17) bearing and had a minimum follow-up of 2 years underwent serum metal analysis. No differences in serum cobalt levels (mean, 0.14 ng/mL [range, 0.075 to 0.29 ng/mL] versus 0.21 ng/mL [range, 0.075 to 0.57 ng/mL]; p = 0.22) or chromium levels (mean, 0.14 ng/mL [range, 0.05 to 0.50 ng/mL] versus 0.12 ng/mL [range, 0.05 to 0.35 ng/mL]; p = 0.65) were identified between the modular dual-mobility and conventional cohorts, respectively, at the 2-year postoperative time point. Conclusions: There were no significant differences in serum cobalt or chromium levels at 1 and 2 years postoperatively in patients who received a ceramic femoral head and this specific dual-mobility bearing compared with a ceramic head and a conventional acetabular component. While modest expected elevations in postoperative relative to preoperative serum cobalt and chromium levels were observed in the dual-mobility group, in no case did the cobalt level exceed the laboratory reference range or the threshold of 1 ng/mL that has been associated with adverse local tissue reactions due to mechanically assisted crevice corrosion. Level of Evidence: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.
No takes yet. Share an insight, caveat, or question.
DeBenedetti et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: