Key result
Novel volume-based CMR method correlates highly with traditional phase-contrast methods for estimating RV-PA coupling.
Why the study?
Current CMR evaluation of RV-PA coupling requires PA flow assessment, and estimating coupling using volumetric RVSV over RVESV had not been tested, specifically in the presence of TR.
Does a novel volume-based CMR method accurately estimate RV-PA coupling compared to the traditional phase-contrast method in patients with varying degrees of tricuspid regurgitation?
Observational (n=404)
No
Does a novel volume-based CMR method accurately estimate RV-PA coupling compared to the traditional phase-contrast method in patients with varying degrees of tricuspid regurgitation?
Effect estimate: Correlation coefficient 0.851
p-value: p=<0.001
RV-PA coupling can be accurately estimated using standard CMR cine sequences without the need for phase-contrast imaging, showing excellent agreement with the traditional method even in patients with significant tricuspid regurgitation.
Supports volume-based RV-PA coupling estimation on routine cine CMR; leaves open prospective outcome validation before clinical adoption.
Background Right ventricular–pulmonary arterial (RV–PA) coupling is a key parameter in evaluating right heart function and adaptation of the RV to afterload. Current Cardiac Magnetic Resonance (CMR) RV-PA coupling evaluation requires from PA flow assessment. In the absence of tricuspid regurgitation (TR), the ratio of right ventricular stroke volume (RVSV) assessed with volumetric assessment over RV end-sistolic volume (RVESV) could be applied. However, this method has not been tested, specifically in presence of TR. Purpose To demonstrate a novel method for estimating RV–PA coupling using RV volumes derived from standard cine CMR sequences, without the need of phase-contrast sequences or flow-derived parameters and investigating the correlation with the traditional method according to the TR grade. Methods A retrospective, single-center, observational study was conducted including 404 patients (64.6% male, mean age of 55 years) who underwent CMR for any clinical indication and whose scans included phase-contrast sequences of PA between January 2020 and January 2025. RV–PA coupling was estimated using a novel approach that relies exclusively on RV volumes derived from steady-state free precession (SSFP) cine sequences, avoiding the need for phase-contrast imaging. Specifically, the RVSV was calculated as the difference between RV end-diastolic volume (RVEDV) and RVESV, and RV–PA coupling was defined as the ratio of this calculated as RVSV to RVESV. Results The mean indexed RVEDV was 78 ml/m², the mean indexed RVESV was 37 ml/m², the mean RVSV was 75 ml, and the mean RV ejection fraction was 53%. There were 89 patients without TR, 144 with mild TR, 74 with moderate TR, 33 with severe TR, and 8 patients with massive or torrential TR. RV-PA coupling was calculated using the traditional method with phase contrast sequence data, resulting in a mean value of 1.24; and using the new proposed method based on RV volumetry from cine sequences, yielding a mean value of 1.31. In the overall cohort of 404 patients, the correlation coefficient between both methods was 0.851 (p < 0.001). When excluding patients with massive and torrential TR, the correlation improved progressively as TR severity decreased, reaching a correlation of up to 0.990 (p < 0.001) in patients with no TR. Conclusions RV–PA coupling can be accurately estimated using CMR without the need for phase-contrast sequences, by relying solely on RV volumes obtained from cine imaging. This volume-based method demonstrated excellent agreement with the conventional approach, even in patients with significant TR.Correlation between both methods Correlation according to TR grade
No takes yet. Share an insight, caveat, or question.
Garcia et al. (2026) conducted an observational in Tricuspid regurgitation and right ventricular-pulmonary arterial coupling (n=404). Volume-based method for estimating RV-PA coupling from cine CMR sequences vs. Traditional method using phase-contrast sequence data was evaluated on Correlation between the novel volume-based method and the traditional phase-contrast method for estimating RV-PA coupling (Correlation coefficient 0.851, p=<0.001). A novel CMR volume-based method for estimating RV-PA coupling showed excellent correlation with the traditional phase-contrast method (r=0.851, p<0.001), improving up to r=0.990 in patients without TR.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: