Answers are grounded in this paper and cite their sources.
This report analyzes retinal irradiances from He-Ne lasers, indicating safe exposure distances.
This report present an analysis of retinal irradiances from He‐Ne gas CW lasers. Equations are developed for retinal irradiance as a function of viewing distance for typical He‐Ne laser with peaks output powers of 0.5 to 100, milliWatts. The various viewing conditions are described and irradiance equations developed for each. Based on extrapolations from theoretical retinal bourn models and available experimental data several conclusions are stated. (1) Continuous exposure of the eyes to a He‐Ne laser of any power in the laboratory cannot be tolerated. (2) Typical alignment He‐Ne lasers in the range of 0.5 to 5 milliwatts present no retinal hazard from a momentary accidental exposures at distances beyond 300 meters anda re probably safe for continuous exposure at distances beyond 1,000 meters.
No takes yet. Share an insight, caveat, or question.
Paul W. Lappin (1968) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: