Key result
QDOT Micro catheter ablation yields 100% freedom from sustained VT at 12 months.
Why the study?
Does mapping and ablation with the QDOT Micro catheter prevent sustained VT or ICD interventions at 12 months in patients with symptomatic VT?
Observational (n=12)
Does mapping and ablation with the QDOT Micro catheter prevent sustained VT or ICD interventions at 12 months in patients with symptomatic VT?
Answers are grounded in this paper and cite their sources.
The QDOT Micro catheter allows for safe ablation and detects higher voltage electrograms compared to standard mapping, with no VT recurrence at 12 months in a small cohort.
Background Catheter ablation is useful to treat patients with scar‐related heart disease and ventricular tachycardia (VT). QDOT Micro catheter is a next generation catheter. Its optimized temperature control and micro‐electrode technology are designed to provide more efficient and consistent lesion creation with an accurate myocardial substrate analysis. This study aims to compare the myocardial electro‐anatomic maps obtained using QDOT and Pentaray (PR) catheters. Method This study enrolled patients with symptomatic VT and indication to perform CA following the latest guidelines. Myocardial electro‐anatomic maps were obtained using QDOT and Pentaray (PR) catheters. The primary objective was to assess the absence of sustained VTs or ICD interventions 12 months after the procedure. Results Twelve patients were enrolled. The percentage of myocardial scar was higher using QDOTB map (15.5%) compared to PR (13.5%) and QDOTM‐map (9%) (< 0.001). The percentage of myocardial borderzone was higher using QDOTB map (7.5%) compared to PR (6%) and QDOTM‐map (3%) ( p < 0.001). The average EGM amplitude acquired in the myocardial scar was higher in the QDOTM‐map (0.24 mV) compared to PR (0.10 mV) and QDOTB‐map (0.10 mV) ( p < 0.001). The average EGM amplitude acquired in the myocardial borderzone was higher in the QDOTM‐map (1.07 mV) compared to PR (0.80 mV) and QDOTB‐map (0.72 mV) ( p < 0.001). No sustained VT was documented at 12 month FU. No adverse events were documented. Conclusion Microelectrode mapping allows detection of higher voltage electrograms compared to standard bipolar mapping and PR mapping. In our small population, the HPSD protocol was used inside the low voltage areas without acute procedural complications.
No takes yet. Share an insight, caveat, or question.
Monaco et al. (2026) conducted an observational in Ventricular tachycardia (n=12). QDOT Micro catheter vs. Pentaray (PR) catheter was evaluated on Absence of sustained VTs or ICD interventions 12 months after the procedure. In a small cohort of 12 patients, ablation using the QDOT Micro catheter resulted in no sustained ventricular tachycardia or adverse events at 12-month follow-up.