Key result
Fetal weight <3rd centile in TOF linked to ~9-fold higher risk of adverse neonatal outcomes.
Why the study?
Tetralogy of Fallot shows variability in neonatal outcomes, and reliable prenatal predictors are essential for optimizing perinatal management.
Do feto-placental data and prenatal echocardiography predict adverse neonatal outcomes in fetuses with isolated Tetralogy of Fallot?
Cohort (n=129)
Yes
Do feto-placental data and prenatal echocardiography predict adverse neonatal outcomes in fetuses with isolated Tetralogy of Fallot?
Answers are grounded in this paper and cite their sources.
Combining estimated fetal weight with pulmonary valve Doppler in the third trimester can help identify high-risk fetuses with Tetralogy of Fallot who may require prompt neonatal intervention.
INTRODUCTION: Tetralogy of Fallot (ToF) shows variability in neonatal outcomes, and identifying reliable prenatal predictors is essential for optimizing perinatal management. The aim of this study was to determine the prognostic value of feto-placental data and prenatal echocardiography in the third trimester in ToF and to compare these findings with a matched control population. MATERIAL AND METHODS: Multicenter prospective cohort study (2011-2023) at two referral centers (BCNatal and University Hospital of Gießen and Marburg). The cohort included 63 fetuses with isolated ToF and 66 healthy controls. All fetuses underwent a third trimester ultrasound and comprehensive echocardiography with 2D speckle tracking. Severe small-for-gestational age (SGA) was defined as estimated fetal weight (EFW) below the third percentile. Adverse composite outcomes were defined as the need for prostaglandin infusion, surgery or ductal stenting, corrective surgery before 3 months, and/or neonatal intensive care unit stay ≥7 days. The association of feto-placental and cardiac data with adverse composite outcome was evaluated. RESULTS: Compared with controls, ToF fetuses showed higher rates of severe SGA (19% vs. 0%, p < 0.001). Cardiac findings showed mild biventricular concentric hypertrophy (relative wall thickness ToF 0.7 [0.5-0.9] vs. controls 0.5 [0.5-0.6], p = 0.001), and reduced deformation (right and left ventricular global longitudinal strain: ToF -17.3% ± 3.8 vs. controls -19.3% ± 3.1, p = 0.001; ToF -18.0% ± 3.8 vs. controls -20.9% ± 3.45, p < 0.001), regardless of placental dysfunction. The adverse composite outcome occurred in 29.3% of ToF cases with pulmonary stenosis. Within this group, EFW <3rd centile (adjusted OR 9.17) and PV peak systolic velocity (aOR 1.03) showed the strongest association with adverse outcomes. Their combined performance yielded an AUC of 0.734, with a predictive value of 71.4% at a 20% false-positive rate. Assessed individually, the AUC was 0.650 for PV peak systolic velocity and 0.639 for estimated fetal weight. Optimal PV Doppler cutoff values were >70 cm/s when EFW was <3rd centile, and >144 cm/s when EFW was above the 3rd centile. CONCLUSIONS: Combining EFW with PV artery Doppler may allow identification of a high-risk subgroup of ToF-PS fetuses who may benefit from closer prenatal monitoring and prompt neonatal care.
No takes yet. Share an insight, caveat, or question.
Nogué et al. (2026) conducted a cohort in Tetralogy of Fallot (n=129). Estimated fetal weight <3rd centile vs. Estimated fetal weight ≥3rd centile was evaluated on Adverse composite outcome (need for prostaglandin infusion, surgery or ductal stenting, corrective surgery before 3 months, and/or NICU stay ≥7 days) (aOR 9.17). In fetuses with Tetralogy of Fallot and pulmonary stenosis, estimated fetal weight <3rd centile was strongly associated with adverse neonatal outcomes.
Synapse has enriched 10 related papers. Consider them for comparative context: