Key result
OMRON M2 Intelli IT+ meets ISO accuracy standards for home BP monitoring in children and adults.
Why the study?
The accuracy of the OMRON M2 Intelli IT+ brachial device for blood pressure measurement in children and adults according to the ISO 81060-2:2018/AMD 2:2024 standard was not established.
Does the OMRON M2 Intelli IT+ brachial device accurately measure blood pressure in children and adults compared to reference observer measurements?
Cross-Sectional (n=85)
Does the OMRON M2 Intelli IT+ brachial device accurately measure blood pressure in children and adults compared to reference observer measurements?
The OMRON M2 Intelli IT+ brachial blood pressure device meets ISO accuracy standards for home blood pressure monitoring in both children and adults.
Answers are grounded in this paper and cite their sources.
Supports confident home BP monitoring in children and adults; extends the pool of validated devices for hypertension management and research.
OBJECTIVE: This study aimed to assess the accuracy of the OMRON M2 Intelli IT+ (HEM-7146T2-EBK) brachial device for BP measurement in children and adults, according to the International Organization for Standardization (ISO) 81060-2:2018/AMD 2:2024 Standard. METHODS: OMRON M2 Intelli IT+ is an oscillometric device designed to measure BP at the brachial level. This study adhered to the ISO 81060-2:2018/AMD 2:2024 protocol and employed the same arm sequential BP measurement method. A total of 85 participants meeting the protocol-specified age, sex, BP, and cuff distribution criteria were included. The accuracy analysis utilized criterion 1 and criterion 2 defined in the ISO protocol. RESULTS: Eighty-seven individuals were selected; two were excluded because of high BP variability ( n = 1) and arrhythmia ( n = 1). Eighty-five participants (50 adults and 35 children) were included. Mean BP differences between the observer measurements were -0.1 ± 2.1/0.5 ± 1.9 mmHg [systolic BP (SBP)/diastolic BP (DBP)]. In the children and adult population ( n = 85), criterion 1, the mean BP differences between the reference measurements and the device were -2.1 ± 4.4/-0.3 ± 3.7 mmHg for SBP and DBP (≤5 ± 8 mmHg); criterion 2 was 3.1/2.9 mmHg for SBP and DBP (≤6.62/6.95 mmHg). In the children's population ( n = 35), criterion 1 values were -3.7 ± 4.0/-1.1 ± 4.1 mmHg for SBP and DBP (≤5 ± 8 mmHg). CONCLUSION: The OMRON M2 Intelli IT+ (HEM-7146T2-EBK) device meets the requirements of the ISO 81060-2:2018/AMD 2:2024 protocol, supporting its use in children and adults for home BP monitoring.
No takes yet. Share an insight, caveat, or question.
Avagyan et al. (2026) reported a cross-sectional. OMRON M2 Intelli IT+ (HEM-7146T2-EBK) device vs. Reference observer measurements was evaluated on Mean BP differences between reference measurements and the device (ISO criterion 1 and 2) (MD -2.1 ± 4.4 mmHg (SBP) and -0.3 ± 3.7 mmHg (DBP)). The OMRON M2 Intelli IT+ device met ISO accuracy requirements for home blood pressure monitoring in children and adults, with mean differences of -2.1 ± 4.4 mmHg (SBP) and -0.3 ± 3.7 mmHg (DBP).
Synapse has enriched 10 related papers. Consider them for comparative context: