Synapse
December 18, 2008Magnetic Resonance in Medicine144 citationsOpen Access

3D blood flow characteristics in the carotid artery bifurcation assessed by flow‐sensitive 4D MRI at 3T

View Full Paper
AHAndreas HarloffFAF. AlbrechtJSJoachim Spreer

Structured PICO

Does flow-sensitive 4D MRI at 3T accurately quantify and visualize 3D blood flow characteristics in the carotid artery bifurcation compared to duplex sonography?

P
Population
19 subjects (10 healthy volunteers and 9 patients with internal carotid artery (ICA) stenosis ≥50%)
I
Intervention
Flow-sensitive 4D MRI at 3T
C
Comparator
Duplex sonography (DS) and healthy volunteer baseline
O
Outcome
Absolute and mean blood velocities, pulsatility index (PI), resistance index (RI), and 3D blood flow patterns (filling and helical flow)surrogate

Flow-sensitive 4D MRI at 3T is feasible for quantifying and visualizing physiological and pathological 3D blood flow patterns in the carotid artery bifurcation, though it underestimates absolute velocities compared to duplex sonography.

Abstract

To determine three-dimensional (3D) blood flow patterns in the carotid bifurcation, 10 healthy volunteers and nine patients with internal carotid artery (ICA) stenosis > or =50% were examined by flow-sensitive 4D MRI at 3T. Absolute and mean blood velocities, pulsatility index (PI), and resistance index (RI) were measured in the common carotid arteries (CCAs) by duplex sonography (DS) and compared with flow-sensitive 4D MRI. Furthermore, 3D MRI blood flow patterns in the carotid bifurcation of volunteers and patients before and after recanalization were graded by two independent readers. Blood flow velocities measured by MRI were 31-39% lower than in DS. However, PI and RI differed by only 13-16%. Rating of 3D flow characteristics in the ICA revealed consistent patterns for filling and helical flow in volunteers. In patients with ICA stenosis, 3D blood flow visualization was successfully employed to detect markedly altered filling and helical flow patterns (forward-moving spiral flow) in the ICA bulb and to evaluate the effect of revascularization, which restored filling and helical flow. Our results demonstrate the feasibility of flow-sensitive 4D MRI for the quantification and 3D visualization of physiological and pathological flow patterns in the carotid artery bifurcation.