Why the study?
Does three-dimensional fractal analysis of 99mTc-MAA SPECT images enable noninvasive evaluation of response to balloon pulmonary angioplasty in CTEPH patients?
Does three-dimensional fractal analysis of 99mTc-MAA SPECT images enable noninvasive evaluation of response to balloon pulmonary angioplasty in CTEPH patients?
Three-dimensional fractal analysis of SPECT images provides a noninvasive method to evaluate treatment response to balloon pulmonary angioplasty in patients with CTEPH.
Answers are grounded in this paper and cite their sources.
May support noninvasive BPA response monitoring in CTEPH; leaves open prospective validation before clinical use.
3D-FA using Tc-MAA SPECT pulmonary perfusion scintigraphy enables a noninvasive evaluation of the response of CTEPH patients to BPA.
No takes yet. Share an insight, caveat, or question.
Maruoka et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: