Key result
Large-bore mechanical thrombectomy with bivalirudin lowers mean PAP by ~4 mm Hg and resolves respiratory failure.
Why the study?
Management of pulmonary embolism after CABG with concurrent heparin-induced thrombocytopenia is challenging due to contraindications to thrombolytic and heparin-based therapies.
Does large-bore mechanical thrombectomy with intraprocedural bivalirudin achieve effective reperfusion and clinical improvement in a post-CABG patient with intermediate- to high-risk pulmonary embolism and heparin-induced thrombocytopenia?
Case Report (n=1)
No
Does large-bore mechanical thrombectomy with intraprocedural bivalirudin achieve effective reperfusion and clinical improvement in a post-CABG patient with intermediate- to high-risk pulmonary embolism and heparin-induced thrombocytopenia?
Demonstrates the feasibility and safety of large-bore mechanical pulmonary thrombectomy using intraprocedural bivalirudin in patients with intermediate- to high-risk PE when recent cardiac surgery and active HIT contraindicate both systemic thrombolysis and heparin.
Answers are grounded in this paper and cite their sources.
May support bivalirudin during large-bore thrombectomy in post-CABG HIT patients with PE; leaves open safety and efficacy in prospective cohorts.
BACKGROUND: Pulmonary embolism (PE) after coronary artery bypass grafting (CABG) is a rare but high-risk event. Management is challenging when PE occurs with heparin-induced thrombocytopenia (HIT), limiting thrombolytic and heparin-based strategies. CASE SUMMARY: A 59-year-old man developed hypoxemic respiratory failure within 2 weeks after CABG. Computed tomography angiography demonstrated bilateral main and lobar PEs with right-heart strain. HIT was confirmed by studies. Given recent surgery and active HIT, thrombolysis and heparin were contraindicated. He underwent urgent bilateral large-bore mechanical thrombectomy with intraprocedural bivalirudin, resulting in clot reduction and respiratory failure resolution. DISCUSSION: This case demonstrates the feasibility of large-bore mechanical thrombectomy with bivalirudin for post-CABG intermediate- to high-risk PE with HIT. Published experience with exclusive bivalirudin during large-bore pulmonary thrombectomy remains limited, and this case adds to the evidence for postsurgical PE management. TAKE-HOME MESSAGE: Large-bore mechanical thrombectomy may provide effective reperfusion when thrombolysis is contraindicated, with bivalirudin serving as a nonheparin anticoagulant in active HIT.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2026) conducted a case report in Post-CABG intermediate- to high-risk pulmonary embolism with heparin-induced thrombocytopenia (HIT) (n=1). Large-bore mechanical aspiration thrombectomy (17-F Penumbra Element / Penumbra Lightning Flash system) with intraprocedural bivalirudin anticoagulation was evaluated on Clot burden reduction, mean pulmonary arterial pressure, and resolution of hypoxemic respiratory failure. Large-bore mechanical thrombectomy with intraprocedural bivalirudin reduced mean pulmonary arterial pressure from 28 to 24 mm Hg and resolved respiratory failure within 24 hours.
Synapse has enriched 10 related papers. Consider them for comparative context: