Why the study?
Does early electrogram morphology and screw-in-to-bottom time (<6 minutes) predict a favorable intraoperative R-wave amplitude increase in patients undergoing right ventricular septal active fixation lead implantation?
Cohort (n=109)
No
Does early electrogram morphology and screw-in-to-bottom time (<6 minutes) predict a favorable intraoperative R-wave amplitude increase in patients undergoing right ventricular septal active fixation lead implantation?
Evaluating early electrogram R-wave-to-COI ratios and observing R-wave amplitude trends for 5 to 6 minutes post-fixation allows prediction of favorable R-wave recovery, potentially avoiding unnecessary lead repositioning during RV septal pacing.
Answers are grounded in this paper and cite their sources.
May support brief post-fixation R-wave monitoring in RV septal leads; leaves open whether this guides repositioning decisions.
BACKGROUND: Pacing threshold adequacy and lead stability can be predicted from the magnitude of the current of injury (COI) immediately after active fixation. However, intraoperative R-wave amplitude often fluctuates despite sufficient COI. OBJECTIVES: The authors aimed to assess whether R-wave amplitude fluctuations are associated with the COI magnitude and can be predicted from early electrogram (EGM) patterns. METHODS: EGMs of 109 cases of right ventricular pacing on the septum were continuously recorded from implantation to generator connection. R-wave amplitude fluctuation patterns were categorized as Dipper type (transient decrease followed by an increase), Riser type (continuous increase), and Other type. The primary outcome was a favorable R-wave amplitude increase, defined as the final value exceeding the initial value. RESULTS: Among the 109 cases, 65 (60%) exhibited Dipper-type and 41 (38%) showed Riser-type R-wave fluctuation patterns. In the Dipper-type patterns, initial EGMs showed R-wave amplitude < COI, which subsequently shifted to R-wave amplitude > COI patterns. Favorable amplitude increases occurred in 34 (52%) of the Dipper-type cases and were associated with shorter times to the lowest R-wave amplitude, with 6 minutes being identified as optimal for prediction (sensitivity: 0.82, specificity: 0.61). All the Riser-type patterns exhibited favorable amplitude increases, with consistent R-wave amplitude > COI patterns. CONCLUSIONS: Most intraoperative R-wave amplitude fluctuations in successful lead implantations follow Dipper- or Riser-type patterns. Favorable R-wave amplitude increases can be predicted within 6 minutes post fixation using early EGM patterns.
No takes yet. Share an insight, caveat, or question.
Oshima et al. (2026) conducted a cohort in Pacemaker or CRT-P recipients undergoing right ventricular septal pacing lead implantation (n=109). Screw-in-to-bottom time (SBT) <6 minutes and intraoperative R-wave amplitude fluctuation pattern (Dipper vs Riser type) vs. Screw-in-to-bottom time (SBT) >=6 minutes and Dipper/Other R-wave fluctuation patterns was evaluated on Favorable R-wave amplitude increase (successful lead implantation with final recorded R-wave amplitude exceeding that measured immediately after lead fixation) (OR 15.3, 95% CI 4.54-51.3, p=<0.001).