This is the authors' abstract. We don't add key points for this paper.
We present the design and analysis of a graphene metasurface-based cross polarization converter operating within the terahertz gap for detecting biomolecules over a broad spectral range, taking the SARS-CoV-2 virus as a specific example. To the best of our knowledge, our design reports the widest band of operation in the THz region of a graphene-based metasensor. Each meta-atom comprises a graphene pattern on silicon dioxide atop a continuous gold layer and exhibits near-unity cross polarization conversion ratio (PCR) and a 90% PCR bandwidth of 0.926 THz within the desired band (1.88 THz-2.81 THz). The proposed device demonstrates additional benefits which include a thin configuration ( <tex-math notation="LaTeX">λ </tex-math> /7.84) and compact lattice size ( <tex-math notation="LaTeX">λ </tex-math> /10.66), which are significantly better than other recently reported graphene metasurface biosensors. The device provides a sensitivity up to 490 GHz/RIU and a figure of merit (FoM) of 0.377 over a wide span of 0.926 THz within the terahertz gap. The electromagnetic response of this device has been validated via rigorous numerical analyses of simulated outputs as well as by developing a detailed circuit model representation of the same. The device demonstrates angular stability of nearly 40° under oblique incidence of the incident wave.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Ghosh et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: