Key result
Sinus plication during BAV repair linked to lower 1-year peak pressure gradients and maximum velocities.
Why the study?
Postoperative stenosis negatively affects durability after bicuspid aortic valve valvuloplasty, and the haemodynamic efficacy of sinus plication to avoid stenosis after asymmetrical BAV repair was evaluated.
Does sinus plication improve haemodynamic outcomes at 1 year in patients undergoing bicuspid aortic valve repair for moderate-severe aortic regurgitation?
Cohort (n=41)
Does sinus plication improve haemodynamic outcomes at 1 year in patients undergoing bicuspid aortic valve repair for moderate-severe aortic regurgitation?
Sinus plication during bicuspid aortic valve repair may enhance haemodynamic stability by lowering peak pressure gradients and maximum flow velocities at 1 year.
Answers are grounded in this paper and cite their sources.
May support sinus plication in BAV repair; leaves open haemodynamic benefit pending randomized confirmation before practice change.
OBJECTIVES: Postoperative stenosis negatively affects durability after bicuspid aortic valve (BAV) valvuloplasty. This study was performed to evaluate the haemodynamic efficacy of sinus plication (SP) to avoid stenosis after asymmetrical BAV repair. METHODS: Between 2018 and 2023, 41 patients with BAV (33.3 ± 11.5 years, 40 males) with moderate-severe aortic regurgitation (AR) underwent aortic valve repair with (SP group, n = 14) or without (NSP group, n = 27) SP. SP was performed to reduce the circumference of the fused sinus and restore sinus contour symmetry. Preoperative and postoperative haemodynamic parameters were assessed at discharge and 1 year using transthoracic echocardiography. RESULTS: No deaths occurred within 1 year after surgery in either group. AR was well controlled and adequate left ventricular reverse remodelling was observed in both the groups up to 1 year postoperatively. At 1 year, lower transvalvular peak pressure gradient (PG) and maximum transvalvular flow velocity (Vmax) were observed in the SP group (peak PG: 17.7 ± 5.5 mmHg; % change -8.8% ± 1.1%, Vmax: 1.9 ± 0.31 m/s; % change -13.1% ± 2.1%) compared with the NSP group (peak PG: 24.7 ± 9.6 mmHg; +8.8% ± 1.3%, Vmax: 2.58 ± 0.62 m/s; +9.3% ± 2.5%), while there were no clear differences in % changes of peak PG or Vmax between the groups after adjustment for covariates. CONCLUSIONS: In BAV repair, SP was potentially associated with lower peak PG and Vmax at 1 year. These findings suggest that SP may enhance haemodynamic stability in BAV repair.
No takes yet. Share an insight, caveat, or question.
Maeda et al. (2026) conducted a cohort in Bicuspid aortic valve (BAV) with moderate-severe aortic regurgitation (n=41). Sinus plication vs. No sinus plication was evaluated on Transvalvular peak pressure gradient at 1 year (mmHg). Sinus plication during bicuspid aortic valve repair yielded lower unadjusted peak pressure gradients at 1 year (17.7 vs 24.7 mmHg), but differences were not significant after covariate adjustment.