Key result
Intracoronary imaging guides individualized treatment for ISR persisting at ~2% annually despite modern DES.
Why the study?
Despite improvements in drug-eluting stent technologies, in-stent restenosis still occurs at 1%-2% per year, and mechanisms, imaging characterization, and treatment strategies have evolved.
This review highlights the multifactorial mechanisms of in-stent restenosis and recommends an individualized treatment approach guided by intracoronary imaging.
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“In-stent restenosis still remains a major clinical problem. Despite the advent of a new generation of drug-eluting stents, this will be the main cause of stent failure.”
“In-stent restenosis isn't particularly common, but it does happen. It seems that some patients are more prone to this than others, and we don't yet fully understand why that is.”
“As an interventional cardiologist, one of the biggest gaps that we've had in the coronary space in the United States was the lack of a drug-coated balloon to be able to treat patients with ISR. Traditionally when patients have stents that restenose, they're treated with another stent. But that means leaving behind another layer of metal within existing stents, and we generally don't want to put more and more layers of metal inside an artery, especially if we can avoid it.”
Supports imaging-guided individualized ISR therapy; leaves open novel prevention strategies for residual risk.
The introduction and subsequent iterations of drug-eluting stent technologies have substantially improved the efficacy and safety of percutaneous coronary interventions. However, the incidence of in-stent restenosis (ISR) and the resultant need for repeated revascularization still occur at a rate of 1%-2% per year. Given that millions of drug-eluting stents are implanted each year around the globe, ISR can be considered as a pathologic entity of public health significance. The mechanisms of ISR are multifactorial. Since the first description of the angiographic patterns of ISR, the advent of intracoronary imaging has further elucidated the mechanisms and patterns of ISR. The armamentarium and treatment strategies of ISR have also evolved over time. Currently, an individualized approach using intracoronary imaging to characterize the underlying substrate of ISR is recommended. In this paper, we comprehensively reviewed the incidence, mechanisms, and imaging characterization of ISR and propose a contemporary treatment algorithm.
No takes yet. Share an insight, caveat, or question.
Giustino et al. (2022) conducted a review in Coronary In-Stent Restenosis. Coronary in-stent restenosis continues to occur at a rate of 1%-2% per year despite advances in drug-eluting stent technologies, necessitating individualized treatment using intracoronary imaging.