This research develops a CMOS image sensor with enhanced pixel array and readout circuit, indicating advancements in ultrafast imaging technology.
Microchannel plate gated framing camera is commonly used in inertial confinement fusion diagnostics. However, it is a vacuum electronic device with bulkiness and non-single-line-of-sight imaging. To reduce the size of the camera and achieve a single line of sight image, a CMOS image sensor composed of a pixel unit and a readout circuit is presented to form the framing camera. The CMOS image sensor has a 32 × 32 × 4 pixel array with ultrashort shutter-time and four-frame imaging. The pixel array and analog to digital converter (ADC) readout circuit are designed using a standard 0.18 μm CMOS process. The pixel array includes 5T structured pixel units, a voltage-controlled delay, a clock tree and the row decoding scan circuits. A temporal resolution of 65 ps for the pixel circuit is achieved. The ADC readout circuit is composed of a counter, a comparator, a ramp generator and a register, which operates at a sampling frequency of 24.41 kS/s. An effective number of bits of 11.3, a spurious free dynamic range (SFDR) of 73.4 dB, and a signal-to-noise ratio (SNR) of 70.0 dB for the ADC are achieved. The CMOS image sensor will provide a novel and important imaging method for the field of ultrafast science.