Why the study?
What is the long-term performance and failure rate of autografts in the second post-operative decade after the Ross procedure?
What is the long-term performance and failure rate of autografts in the second post-operative decade after the Ross procedure?
While late survival after the Ross procedure is good, high rates of autograft failure in the second decade necessitate careful long-term monitoring, particularly in patients with pre-operative aortic regurgitation.
Answers are grounded in this paper and cite their sources.
Supports vigilant long-term surveillance after Ross; leaves open predictors of late autograft failure.
We observed good late survival in patients undergoing autograft procedure without reinforcement techniques. However, over half of the autografts failed prior to the end of the second decade. The reoperation rate and the results of echocardiographic measurements over time underline the importance of careful monitoring especially in the second decade after the initial autograft operation and in particular in patients with pre-operative AR.
No takes yet. Share an insight, caveat, or question.
Mokhles et al. (2012) studied this question.