Key result
Aortic valve calcium ≥3000 AU linked to ~67% higher risk of moderate or greater PVL after TAVR.
Why the study?
Aortic valve calcium score is associated with an increased risk of paravalvular leak after TAVR, but whether valve platform performance differs according to calcium burden remained unclear.
Does a high aortic valve calcium burden increase the risk of paravalvular leak in patients undergoing TAVR with balloon-expandable or self-expanding valves?
Cohort (n=4,483)
Does a high aortic valve calcium burden increase the risk of paravalvular leak in patients undergoing TAVR with balloon-expandable or self-expanding valves?
Answers are grounded in this paper and cite their sources.
High aortic valve calcium burden (≥3000 AU) and the use of self-expanding valves are independent predictors of moderate or greater paravalvular leak after TAVR, although contemporary-generation valves attenuate these differences.
Background: Aortic valve calcium score (AVCS) is associated with an increased risk of paravalvular leak (PVL) after Transcatheter aortic valve replacement (TAVR). We aimed to evaluate the association between AVCS burden and procedural outcomes, particularly PVL, and to determine whether valve platform performance differs according to calcium burden. Methods: This study included patients with severe aortic stenosis undergoing TAVR with balloon-expandable (Sapien platform) or self-expanding (Evolut and Navitor platforms) valves. The primary endpoint was the rate of any and moderate or greater PVLs according to AVCS burden (<3000 vs. ≥3000 AU). Valve platform comparisons were performed within each calcium stratum, and additional analyses evaluated PVLs in contemporary-generation valves. Results: A total of 4483 patients were included, of whom 1134 had an AVCS ≥ 3000 AU, and 3349 had an AVCS < 3000 AU. Any type of PVL occurred more frequently in the AVCS ≥ 3000 group (59% vs. 54%; p = 0.010), as did moderate or greater PVLs (5% vs. 3%; p = 0.011). In multivariable analysis, both SEV implantation and AVCS ≥ 3000 AU were independent predictors of moderate or greater PVL, while the interaction between AVCS burden and valve platform was not significant. When restricted to contemporary-generation valves, PVL rates were lower overall but remained higher in patients with an AVCS ≥ 3000 AU (4.4% vs. 2.4%; p = 0.001), with smaller differences between valve platforms. Conclusions: A higher AVCS is associated with increased PVLs after TAVR. BEVs showed lower rates of moderate or greater PVLs than SEVs, although no statistically significant interaction between AVCS burden and valve platform was observed. With contemporary-generation valves, overall PVL rates were reduced, and platform differences were attenuated.
No takes yet. Share an insight, caveat, or question.
Arow et al. (2026) conducted a cohort in Severe aortic stenosis (n=4,483). Aortic valve calcium score ≥ 3000 AU vs. Aortic valve calcium score < 3000 AU was evaluated on Rate of moderate or greater paravalvular leak (p=0.011). An aortic valve calcium score ≥3000 AU was associated with a higher rate of moderate or greater paravalvular leak after TAVR compared to <3000 AU.
Synapse has enriched 10 related papers. Consider them for comparative context: