Key result
Total AVC independently predicted mild or greater PVL at 1 year post-TAVR, whereas AVC asymmetry did not.
Why the study?
Although total aortic valve calcification burden and self-expandable valves predict paravalvular leak after TAVR, the impact of leaflet-specific calcification asymmetry and its interaction with valve type remained uncertain.
Does leaflet-specific aortic valve calcification asymmetry predict mild or greater paravalvular leak at 1 year in patients undergoing transcatheter aortic valve replacement?
Cohort (n=530)
Does leaflet-specific aortic valve calcification asymmetry predict mild or greater paravalvular leak at 1 year in patients undergoing transcatheter aortic valve replacement?
Total aortic valve calcification burden independently predicts mild or greater paravalvular leak at 1 year following TAVR, whereas leaflet-specific calcification asymmetry and valve type offer no additional predictive value.
Answers are grounded in this paper and cite their sources.
AVC asymmetry may refine PVL risk stratification after TAVR; leaves open whether it should guide valve selection.
Paravalvular leak (PVL) is a significant complication after transcatheter aortic valve replacement (TAVR). Although total aortic valve calcification (AVC) burden and self-expandable valves are predictors of PVL, the impact of leaflet-specific AVC asymmetry remains uncertain. The authors evaluated the association between AVC asymmetry and mild or greater PVL at 1 year after TAVR and its interaction with valve type. Patients undergoing TAVR between January 2022 and May 2025 with preprocedural noncontrast cardiac computed tomography and 1-year transthoracic echocardiography were included. Asymmetric AVC was defined as greater than 50% of total AVC on a single cusp. Among 530 patients (mean age, 79 ± 8 years; 45.5% female), 130 (24.5%) had mild or greater PVL at 1 year. Total AVC was higher in women (1747 vs 1125 AU; P less than .001) and men (2612 vs 2063 AU; P less than .001) with mild or greater PVL, with greater calcification across all cusps. AVC asymmetry was comparable between PVL and non-PVL groups (33.1% vs 41.4%; P = .093). Total AVC independently predicted PVL (adjusted odds ratio [OR], 1.036 per 100 AU; P < .001), whereas asymmetry did not (adjusted OR, 0.912; P = .681). No significant interaction occurred between valve type, AVC asymmetry, and PVL (P = .224). Total AVC independently predicts mild or greater PVL at 1 year after TAVR, whereas leaflet-specific asymmetry and valve type provide no additional predictive value.
No takes yet. Share an insight, caveat, or question.
Basera et al. (2026) conducted a cohort in Aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) (n=530). Asymmetric aortic valve calcification (>50% of total AVC on a single cusp) vs. Non-asymmetric aortic valve calcification was evaluated on Mild or greater paravalvular leak (PVL) at 1 year after TAVR (OR 0.912, p=0.681). Total AVC independently predicted mild or greater PVL at 1 year post-TAVR, whereas AVC asymmetry did not.
Synapse has enriched 10 related papers. Consider them for comparative context: