Why the study?
Bioprosthetic aortic valve degeneration shares pathological similarities with aortic stenosis, where Lp(a) is an established risk factor, but its association with bioprosthetic degeneration remained unknown.
Are higher serum lipoprotein(a) concentrations associated with increased bioprosthetic aortic valve degeneration in patients with bioprosthetic aortic valves?
Are higher serum lipoprotein(a) concentrations associated with increased bioprosthetic aortic valve degeneration in patients with bioprosthetic aortic valves?
Serum lipoprotein(a) concentrations do not appear to be associated with or mediate bioprosthetic aortic valve degeneration over a 2-year follow-up.
Answers are grounded in this paper and cite their sources.
Lp(a) was not associated with bioprosthetic aortic valve degeneration over 2 years; leaves open its role in longer-term durability.
AIMS: Bioprosthetic aortic valve degeneration demonstrates pathological similarities to aortic stenosis. Lipoprotein(a) [Lp(a)] is a well-recognized risk factor for incident aortic stenosis and disease progression. The aim of this study is to investigate whether serum Lp(a) concentrations are associated with bioprosthetic aortic valve degeneration. METHODS AND RESULTS: In a post hoc analysis of a prospective multimodality imaging study (NCT02304276), serum Lp(a) concentrations, echocardiography, contrast-enhanced computed tomography (CT) angiography, and 18F-sodium fluoride (18F-NaF) positron emission tomography (PET) were assessed in patients with bioprosthetic aortic valves. Patients were also followed up for 2 years with serial echocardiography. Serum Lp(a) concentrations [median 19.9 (8.4-76.4) mg/dL] were available in 97 participants (mean age 75 ± 7 years, 54% men). There were no baseline differences across the tertiles of serum Lp(a) concentrations for disease severity assessed by echocardiography [median peak aortic valve velocity: highest tertile 2.5 (2.3-2.9) m/s vs. lower tertiles 2.7 (2.4-3.0) m/s, P = 0.204], or valve degeneration on CT angiography (highest tertile n = 8 vs. lower tertiles n = 12, P = 0.552) and 18F-NaF PET (median tissue-to-background ratio: highest tertile 1.13 (1.05-1.41) vs. lower tertiles 1.17 (1.06-1.53), P = 0.889]. After 2 years of follow-up, there were no differences in annualized change in bioprosthetic hemodynamic progression [change in peak aortic valve velocity: highest tertile [0.0 (-0.1-0.2) m/s/year vs. lower tertiles 0.1 (0.0-0.2) m/s/year, P = 0.528] or the development of structural valve degeneration. CONCLUSION: Serum lipoprotein(a) concentrations do not appear to be a major determinant or mediator of bioprosthetic aortic valve degeneration.
No takes yet. Share an insight, caveat, or question.
Botezatu et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: