Why the study?
Right ventricular pacing causes delayed activation of remote ventricular segments, motivating the use of UHF-ECG to describe ventricular depolarization during pacing at different right ventricular locations.
Does pacing at different right ventricular locations affect ventricular activation delays measured by ultra-high-frequency ECG in patients requiring temporary pacing?
Does pacing at different right ventricular locations affect ventricular activation delays measured by ultra-high-frequency ECG in patients requiring temporary pacing?
Right ventricular inflow tract pacing produces better ventricular synchrony compared to other RV pacing locations with myocardial capture, though nonselective His bundle or right bundle branch capture provides the best synchrony.
Answers are grounded in this paper and cite their sources.
RV inflow tract pacing may reduce dyssynchrony versus outflow tract when His capture is unavailable; leaves open outcome effects in temporary pacing.
BACKGROUND: Right ventricular (RV) pacing causes delayed activation of remote ventricular segments. We used the ultra-high-frequency ECG (UHF-ECG) to describe ventricular depolarization when pacing different RV locations. METHODS: In 51 patients, temporary pacing was performed at the RV septum (mSp); further subclassified as right ventricular inflow tract (RVIT) and right ventricular outflow tract (RVOT) for septal inflow and outflow positions (below or above the plane of His bundle in right anterior oblique), apex, anterior lateral wall, and at the basal RV septum with nonselective His bundle or RBB capture (nsHBorRBBp). The timings of UHF-ECG electrical activations were quantified as left ventricular lateral wall delay (LVLWd; V8 activation delay) and RV lateral wall delay (RVLWd; V1 activation delay). RESULTS: The LVLWd was shortest for nsHBorRBBp (11 ms [95% confidence interval = 5-17]), followed by the RVIT (19 ms [11-26]) and the RVOT (33 ms [27-40]; p < .01 between all of them), although the QRSd for the latter two were the same (153 ms (148-158) vs. 153 ms (148-158); p = .99). RV apical capture not only had a longer LVLWd (34 ms (26-43) compared to mSp (27 ms (20-34), p < .05), but its RVLWd (17 ms (9-25) was also the longest compared to other RV pacing sites (mean values for nsHBorRBBp, mSp, anterior and lateral wall captures being below 6 ms), p < .001 compared to each of them. CONCLUSION: RVIT pacing produces better ventricular synchrony compared to other RV pacing locations with myocardial capture. However, UHF-ECG ventricular dysynchrony seen during RVIT pacing is increased compared to concomitant capture of basal septal myocytes and His bundle or proximal right bundle branch.
No takes yet. Share an insight, caveat, or question.
Čurila et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: