PulseExploreJournal ClubDebatesTrendingResearchersJournals
Instagram
HomeExploreJournal ClubTrending
Synapse
⌘+K
Synapse
April 1, 1996Radiology560 citations

"Black blood" T2-weighted inversion-recovery MR imaging of the heart.

View Full Paper
OSOrlando P. SimonettiJFJ. Paul FinnRWRichard D. White

Key Points

  • The aim is to develop a short-inversion-time inversion-recovery MR imaging technique for the myocardium with reduced artifacts.
  • Implemented a breath-hold, cardiac-triggered STIR sequence with preparatory radio-frequency pulses.
  • Utilized a segmented rapid acquisition with relaxation enhancement (turbo spin echo) readout at 1.0 and 1.5 T.
  • Tested the sequence in phantoms, five healthy volunteers, and three patients with myocardial concerns.
  • Phantom studies confirmed expected sequence behavior with effective fat suppression.
  • In volunteers, successful generation of fat-suppressed heart images with uniform nulling of blood.
  • Two patients showed focal edema consistent with myocardial infarction, while a third had a distinct paracardiac mass.

Abstract

PURPOSE: To develop a short-inversion-time inversion-recovery (STIR) magnetic resonance imaging pulse sequence for evaluating the myocardium that is relatively free of flow and motion artifact. MATERIALS AND METHODS: The authors implemented a breath-hold, cardiac-triggered STIR sequence with preparatory radio-frequency pulses to eliminate signal from flowing blood. A segmented rapid acquisition with relaxation enhancement (turbo spin echo) readout was used, with the inversion-recovery delay adjusted to null fat. The sequence was implemented at 1.0 and 1.5 T and tested in phantoms, five healthy volunteers, and three patients. RESULTS: Phantom studies confirmed the expected behavior of the sequence. In the volunteers, fat-suppressed images of the heart with STIR contrast were generated in a breath-hold period. Blood in the heart chambers was uniformly nulled, and motion artifacts were effectively suppressed. Focal high signal intensity consistent with edema was seen in two patients with acute myocardial infarction; in a third patient, a paracardiac mass was visualized and sharply demarcated relative to normal myocardium. CONCLUSION: Fast STIR imaging of the heart with effective suppression of flow and motion artifacts was implemented. The approach has much potential for high-contrast imaging in a variety of diseases affecting the heart and mediastinum.

Ask AI
Helpful
Bookmark
Share
View Full Paper

Cite This Study

Simonetti et al. (1996) studied this question.

synapsesocial.com/papers/69f69057e405cc4465bc2889https://doi.org/10.1148/radiology.199.1.8633172
Ask AI
Helpful
Bookmark
Share
View Full Paper

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Non-enhanced Multi-contrast 3D Whole-heart MRI for Assessment of Reperfusion Injury in Patients with Acute Myocardial Infarction2024
  2. 2Cardiovascular magnetic resonance of myocardial edema using a short inversion time inversion recovery (STIR) black-blood technique: Diagnostic accuracy of visual and semi-quantitative assessment2012 · 48 citations
  3. 3Inversion‐recovery‐prepared SSFP for cardiac‐phase‐resolved delayed‐enhancement MRI2007 · 46 citations
  4. 4Improved fat water separation with water selective inversion pulse for inversion recovery imaging in cardiac MRI2012 · 13 citations
  5. 5Simultaneous 3D whole‐heart bright‐blood and black blood imaging for cardiovascular anatomy and wall assessment with interleaved T 2 prep‐IR2019 · 17 citations