Key result
Dual-energy lattice-tip catheter ablation appears feasible in mechanical heart valve patients with 0 procedural complications.
Why the study?
Catheter ablation near mechanical prosthetic valves carries risks of catheter-valve interaction and entrapment, prompting evaluation of the feasibility, safety, and efficacy of a dual-energy, lattice-tip catheter in this setting.
Is atrial catheter ablation using a dual-energy, lattice-tip catheter safe and feasible in patients with mechanical heart valves?
Observational (n=9)
Yes
Is atrial catheter ablation using a dual-energy, lattice-tip catheter safe and feasible in patients with mechanical heart valves?
Atrial ablation using a dual-energy, lattice-tip catheter near mechanical heart valves appears feasible and safe without catheter entrapment, though larger studies are needed to confirm these preliminary findings.
May expand ablation access for mechanical valve patients; leaves open larger trials to confirm safety and efficacy.
BACKGROUND: Catheter ablation near mechanical prosthetic valves is associated with a risk of catheter-valve interaction and entrapment. OBJECTIVE: To evaluate the feasibility, safety, and efficacy of atrial ablation using a dual-energy, lattice-tip catheter in patients with mechanical heart valves. METHODS: Consecutive patients undergoing atrial catheter ablation near a mechanical valve using the Sphere-9 catheter were identified at two tertiary centres. Primary safety endpoints included abortion of ablation because of catheter interference and procedural complications. Freedom from atrial tachyarrhythmia during follow-up was assessed as an efficacy endpoint. An in vitro valve interaction testing was additionally performed. RESULTS: Nine patients (median age 59 years; 56% male) were identified. Ablation lines anchored to a mechanical valve were created in six patients, using RFA close to the valve in 5 patients and pulsed-field ablation (PFA) in 1 patient. Interference during ablation leading to abortion of individual applications occurred in three patients, all during RFA, without preventing completion of the intended ablation strategy. No catheter entrapment, valve dysfunction, or procedural adverse events occurred. After a median follow-up of 114 days, all patients were free from recurrent atrial tachyarrhythmias. Bench testing demonstrated no propensity of the lattice-tip catheter to become wedged within a bileaflet mechanical heart valve. CONCLUSION: Atrial ablation using a lattice-tip catheter appears feasible in patients with mechanical heart valves. No catheter entrapment or major complications were observed. However, given the small sample size, these findings should be interpreted as preliminary, and larger studies are needed to better assess safety and clinical outcomes.
No takes yet. Share an insight, caveat, or question.
Keller et al. (2026) conducted an observational in Atrial tachyarrhythmia with mechanical heart valves (n=9). Dual-energy, lattice-tip catheter (Sphere-9) ablation was evaluated on Abortion of ablation because of catheter interference and procedural complications. Atrial ablation using a dual-energy, lattice-tip catheter in patients with mechanical heart valves was feasible, with 0 procedural adverse events or catheter entrapments occurring in 9 patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: