Why the study?
Various methods identify persistent atrial fibrillation substrate, but the relationship between complex fractionated atrial electrograms, electrogram dispersion, and low-voltage areas, and their changes following ablation, required investigation.
Does post-procedural de-escalation of complex fractionated atrial electrograms predict freedom from recurrence in patients with persistent atrial fibrillation undergoing ablation?
Does post-procedural de-escalation of complex fractionated atrial electrograms predict freedom from recurrence in patients with persistent atrial fibrillation undergoing ablation?
Post-procedural de-escalation of complex fractionated atrial electrograms across the left atrium is associated with a lower recurrence of persistent atrial fibrillation following ablation.
Answers are grounded in this paper and cite their sources.
May support CFAE de-escalation as ablation marker in persistent AF; leaves open randomized validation before practice change.
BACKGROUND: Various methods have been used to identify substrate of persistent atrial fibrillation (PeAF) including complex fractionated atrial electrograms (CFAEs), electrogram dispersion, and low-voltage areas (LVAs). This study aims to investigate their relationship and changes following ablation. METHODS AND RESULTS: Consecutive patients with PeAF undergoing catheter ablation were prospectively recruited. High-density left atrial mapping was employed. Repeat mapping was performed after pulmonary vein and posterior wall isolation (PVI + PWI) if atrial fibrillation persisted. Dispersion tags were automatically annotated using a commercially available artificial intelligence system. A total of 32 patients (mean age 64.8 ± 9.7 years, 26 male) were included. In CFAE regions, 93.1 ± 7.5% of the surface had voltage > 0.5 mV, compared to only 17.5 ± 24.5% in the non-CFAE regions. Nearly all dispersion tags (99.3 ± 1.6%) were located within CFAE regions. Postablation mapping (N = 24) revealed a reduction in both CFAE and dispersion tags, prolongation of atrial cycle length, and de-escalation of CFAE sub-types, even in areas remote from ablation targets. During a median follow-up period of 9.0 ± 1.9 months, among the nine patients with CFAE de-escalations across all five regions, only one (11.1%) experienced recurrence. In contrast, eight out of the remaining 15 patients (53.3%) experienced recurrence (p = 0.039). CONCLUSION: Dispersion is associated with CFAEs, predominantly reflecting areas of normal voltage. Regional reductions in CFAE and dispersion burden may occur outside of the directly targeted ablation areas. Post-procedural de-escalation of electrograms across the left atrium might suggest a potential indicator for PVI + PWI responders; however, further studies are warranted.
No takes yet. Share an insight, caveat, or question.
Liu et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: