Answers are grounded in this paper and cite their sources.
Cross-sectional study found low incidence of adverse reactions in iodinated contrast use, indicating monitoring importance for safety.
Objectives Iodinated contrast media (ICM) are widely used in radiological imaging to improve diagnostic accuracy. Despite advances in low-osmolality, non-ionic agents, immediate and delayed hypersensitivity reactions remain a clinical concern. This study aimed to determine the incidence and severity of contrast-related reactions and to identify associated patient and procedural risk factors. Material and Methods A cross-sectional observational study was conducted on 350 patients undergoing contrast-enhanced radiological procedures. Pre-procedural screening included medical history, allergy assessment, medication review, renal function testing, and baseline vital signs. All patients were monitored for 30 min post-contrast administration to detect adverse reactions. Reactions were classified as mild, moderate, and severe based on American College of Radiology (ACR) guidelines. Descriptive statistics were applied to determine incidence rates and distribution of reactions. Frequencies and percentages were calculated for categorical variables, and cross-tabulation was performed to identify associations with demographic and clinical risk factors. Results Among 350 patients, 7 (2.0%) developed contrast-related adverse reactions. Of these, 4 (57.1%) were mild, and 3 (42.9%) were moderate; no severe or life-threatening events occurred. Reactions were more frequent in patients aged 50-60 years (n = 3, 42.9%), those with diabetes mellitus (n = 3, 42.9%), and patients with a prior history of drug allergy (n = 2, 28.6%). Technical errors during injection were implicated in two cases (28.6%). The most common symptoms were nausea (n = 3, 42.9%), urticaria (n = 2, 28.6%), and dyspnoea (n = 2, 28.6%). All reactions were effectively managed with conservative treatment. Conclusion The study demonstrates a low incidence (2.0%) of iodinated contrast reactions in radiological practice, with no severe outcomes. Modern ICMs are safe when used with appropriate pre-procedural screening and post-administration monitoring. Continued vigilance is recommended, particularly in patients with comorbidities and prior allergic history, to further minimise risk and ensure patient safety.
No takes yet. Share an insight, caveat, or question.
Jha et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: