Why the study?
Limited data are available on the safety, efficacy, and outcomes of S-ICD implantation after transvenous lead extraction of transvenous ICDs.
What are the safety, efficacy, and outcomes of S-ICD implantation in patients who have undergone transvenous lead extraction?
What are the safety, efficacy, and outcomes of S-ICD implantation in patients who have undergone transvenous lead extraction?
S-ICD is a safe and effective alternative after transvenous ICD explantation, with mortality primarily driven by underlying heart failure and comorbidities rather than device-related issues.
Answers are grounded in this paper and cite their sources.
S-ICD may be considered post-extraction in select patients; leaves open randomized confirmation before practice change.
BACKGROUND: Subcutaneous implantable cardioverter defibrillator (S-ICD) is a suitable alternative for transvenous ICD (TV-ICD) patients who have undergone transvenous lead extraction (TLE). Limited data are available on the outcome of S-ICD patients implanted after TLE. We assessed the safety, efficacy, and outcome of S-ICD implantation after TLE of TV-ICD. METHODS: The study population consisted of 36 consecutive patients with a median age of 52 (44-66) years who underwent S-ICD implantation after TLE of TV-ICD. RESULTS: Indications for TLE were infection (63.9%) and lead malfunction (36.1%). During a median follow-up of 31 months, 3 patients (8.3%) experienced appropriate therapy and 7 patients (19.4%) experienced complications including inappropriate therapy (n = 4; 11.1%), isolated pocket erosion (n = 2; 5.5%), and ineffective therapy (n = 1; 2.8%). No lead/hardware dysfunction was reported. Premature device explantation occurred in 4 patients (11%). Eight patients (22.2%) died during follow-up, six of them (75%) because of refractory heart failure (HF). There were no S-ICD-related deaths. Predictors of mortality included NYHA class ≥ 2 (HR 5.05; 95% CI 1.00-26.38; p = 0.04), hypertension (HR 22.72; 95% CI 1.05-26.31; p = 0.02), diabetes (HR 10.64; 95% CI 2.05-55.60; p = 0.001) and ischemic heart disease (HR 5.92; 95% CI 1.17-30.30; p = 0.01). CONCLUSION: Our study provides evidences on the use of S-ICD as an alternative after TV-ICD explantation for both infection and lead failure. Mortality of S-ICD patients who underwent TV-ICD explantation does not appear to be correlated with the presence of a prior infection, S-ICD therapy (appropriate or inappropriate), or S-ICD complications but rather to worsening of HF or other comorbidities.
No takes yet. Share an insight, caveat, or question.
Giacomin et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: