Key result
Heart transplant recipients require permanent pacemakers at a ~5% rate with stable long-term pacing indices.
Why the study?
Despite graft-related complications after heart transplantation, evidence on the long-term stability of pacing indices is lacking, and early post-transplant sinus node dysfunction indications remain poorly characterized.
What is the incidence, indication, and long-term stability of pacing indices in heart transplant recipients receiving a permanent pacemaker?
Observational (n=861)
No
What is the incidence, indication, and long-term stability of pacing indices in heart transplant recipients receiving a permanent pacemaker?
Pacing indices in heart transplant recipients remain stable long-term, similar to native hearts, except for a progressive decrease in P-wave amplitude.
Pacing indices appear stable long-term after heart transplant; extends sparse observational data but should not yet alter surveillance practice.
BACKGROUND: Approximately 10% of heart transplant (HT) recipients require a pacemaker (PM) implant. Despite graft-related complications such as rejection, cardiac allograft vasculopathy and fibrosis, there is no evidence on the long-term stability of pacing indices. Moreover, one of the most common indications for PM implant is early post-transplant sinus node dysfunction (SND), although this is reversible in many cases. METHODS AND RESULTS: A retrospective observational study including all HT recipients at our institution who underwent permanent PM implantation between April 1991 and January 2023 was conducted. The incidence of PM implantation, indications for PM implantation and changes in pacing indices were evaluated. A total of 861 adult HT were performed (92.1% using bicaval anastomosis technique), and 46 received a permanent pacemaker (cumulative incidence 5.3%) over a median follow-up of 7.9 years (IQR 2.5-15.1 years). Only one patient (2%) received a PM due to early post-HT SND. The median PM follow-up time was 5.4 years (IQR 2.0-8.1 years). Atrial and ventricular leads showed an initial impedance drop (p < 0.001 both) and an initial capture threshold increase (p < 0.001 and p = 0.003, respectively) with subsequent stabilization. R-wave amplitude remained stable, but there was a drop in P-wave amplitude (p = 0.026). CONCLUSIONS: Pacing indices remained stable and showed a behavior similar to that of native hearts except for a progressive decrease in P-wave amplitude, suggesting the need to aim for the highest possible P-wave amplitude during implantation.
No takes yet. Share an insight, caveat, or question.
de‐Aspe et al. (2025) conducted an observational in Heart transplant recipients (n=861). Permanent pacemaker implantation was evaluated on Incidence of PM implantation and changes in pacing indices. Permanent pacemaker implantation was required in 5.3% of heart transplant recipients, with pacing indices remaining stable long-term except for a progressive decrease in P-wave amplitude (p=0.026).