Key result
Permanent pacemaker implantation after orthotopic heart transplantation was associated with a poorer outcome (HR 1.9; 95% CI 1.06-3.46; p=0.031) and a higher rate of fatal septicemia.
Why the study?
Improved posttransplant survival raises questions about pacemaker dependence and the prognostic relevance of permanent pacemaker implantation during prolonged follow-up after orthotopic heart transplantation.
What is the prevalence of pacemaker dependence and the prognostic impact of permanent pacemaker implantation in patients with very long-term follow-up after orthotopic heart transplantation?
Observational (n=183)
What is the prevalence of pacemaker dependence and the prognostic impact of permanent pacemaker implantation in patients with very long-term follow-up after orthotopic heart transplantation?
Effect estimate: HR 1.9 (95% CI 1.06-3.46)
p-value: p=.031
While 26.8% of heart transplant recipients receive a permanent pacemaker, one-third eventually lose pacemaker dependence, and pacemaker implantation is associated with worse long-term survival and fatal septicemia.
BACKGROUND: Orthotopic heart transplantation (OHT) is associated with a high incidence of conduction disturbances (CD) leading to permanent pacemaker (PPM) implantation. However, the improved posttransplant survival raises the question about the pacemaker dependence (PD) in a prolonged follow-up. HYPOTHESIS: The prevalence of PPM in OHT is high but not all patients are PD in a very long-term follow-up. Device implantation has no prognostic relevance. METHODS: We performed a retrospective analysis of patient medical records focusing on device interrogation data at the most recent follow-up. RESULTS: The study population consisted of 183 patients with a mean follow-up of 15.0 ± 6.8 years. One-fourth of the patients had undergone PPM implantation (n = 49, 26.8%). Among these, two-thirds were PD at last follow-up (n = 32, 65.3%). PPM was more often in biatrial OHT and cardiac allograft vasculopathy (OR 3.0, 95% CI 1.26-7.29, p = .013 and OR 2.0, 95% CI 1.03-3.87, p = .041, respectively). Early sinus node dysfunction (SND) was the most persistent CD. PPM was associated with a poorer outcome in OHT (HR 1.9, 95% CI 1.06-3.46, p = .031) and a higher rate of fatal septicemia (HR 5.1, 95% CI 1.41-18.14, p = .013). CONCLUSIONS: One-fourth of the OHT recipients develop CD requiring PPM implantation, although one-third among these are not PD in follow-up. Early SND is associated with a higher rate of PD. PPM is associated with an inferior prognosis.
No takes yet. Share an insight, caveat, or question.
Alyaydin et al. (2022) conducted an observational in Orthotopic heart transplantation (OHT) (n=183). Permanent pacemaker (PPM) implantation vs. No PPM was evaluated on Outcome in OHT (HR 1.9, 95% CI 1.06-3.46, p=.031). Permanent pacemaker implantation after orthotopic heart transplantation was associated with a poorer outcome (HR 1.9; 95% CI 1.06-3.46; p=0.031) and a higher rate of fatal septicemia.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: