Key result
In-stent Carlino technique enables safe device delivery in 2 cases of uncrossable in-stent CTOs.
Why the study?
In-stent chronic total occlusions frequently demonstrate device uncrossability despite successful wire crossing, presenting a challenge in coronary interventions.
Does the in-stent Carlino technique facilitate device delivery in device-uncrossable in-stent chronic total occlusions?
Case Report (n=2)
No
Does the in-stent Carlino technique facilitate device delivery in device-uncrossable in-stent chronic total occlusions?
The in-stent Carlino technique using controlled contrast injection is a feasible and safe bailout strategy for facilitating device delivery in uncrossable in-stent chronic total occlusions.
Answers are grounded in this paper and cite their sources.
May aid bailout device delivery in uncrossable IS-CTOs; leaves open need for prospective validation before wider use.
Background and aims In-stent chronic total occlusion (IS-CTO) remains a challenging subset of coronary interventions, frequently demonstrating device uncrossability despite successful wire crossing. The in-stent Carlino technique can serve as a feasible and safe bailout strategy for device-uncrossable IS-CTOs. Methods We present two cases of complex IS-CTOs in which successful wire crossing was achieved but device delivery failed despite exhausting appropriate support techniques. In-stent Carlino was performed using controlled contrast injection (0.5 mL) through a wedged microcatheter to create hydraulic plaque modification. Results Both cases achieved successful device delivery following in-stent Carlino application. The technique facilitated microcatheter advancement and subsequent lesion treatment without complications. The metallic stent framework and dense neoatherosclerotic tissue provided natural containment, preventing extension of the dissection to extra-plaque. Conclusions In-stent Carlino offers an effective bailout for device-uncrossable IS-CTOs. Compared with conventional Carlino applications, safety is enhanced by the natural containment provided by the stent architecture.
No takes yet. Share an insight, caveat, or question.
Samir et al. (2026) conducted a case report in Device-uncrossable in-stent chronic total occlusions (IS-CTOs) (n=2). In-stent Carlino technique was evaluated on Successful device delivery and lesion treatment. The in-stent Carlino technique successfully facilitated device delivery and subsequent lesion treatment in two cases of device-uncrossable in-stent chronic total occlusions without complications.