Key result
Core-Knot fasteners during SAVR are linked to ~14 minutes shorter cross-clamp time versus manual knots.
Why the study?
Does the use of an automated fastener (Core-Knot) reduce ischemic time and improve outcomes compared to manually tied knots in patients undergoing surgical aortic valve replacement?
Cohort (n=119)
No
Does the use of an automated fastener (Core-Knot) reduce ischemic time and improve outcomes compared to manually tied knots in patients undergoing surgical aortic valve replacement?
Absolute Event Rate: 70% vs 84%
p-value: p=<0.001
The use of the Core-Knot automated fastener during surgical aortic valve replacement significantly reduces aortic cross-clamp time and postoperative paravalvular aortic regurgitation compared to manual knot tying.
The Core-Knot device is an automatic fastener used mainly in minimally invasive heart valve surgery procedures, to facilitate knot tying. The purpose of this report is to compare ischemic time and outcomes of surgical aortic valve replacements (SAVRs) utilizing the Core-Knot device compared with manually tied knots.Between January, 2014 and December, 2016, 119 patients underwent SAVR in Cape Cod Hospital. We compared patient's characteristics, cross-clamp time, and outcomes of 75 patients who underwent SAVR using Core-Knot to those of 44 operated using manually tied knots.Patient characteristics were similar between groups. Patients in the Core-Knot group had higher preoperative aortic valve area and higher ejection fraction. The use of Core-Knot was associated with reduced aortic cross-clamp time (median 70 vs 84 minutes; P < .001). Patients undergoing SAVR using Core-Knot were less likely to have postoperative aortic regurgitation (P < .001). Early mortality, and also the rates of early adverse events (including all cardiac, neurologic, and renal complications), and the immediate postprocedure echo findings were similar in the 2 groups. In multivariate analysis, the use of Core-Knot was associated with reduced postoperative mean gradient across the aortic valve and reduced occurrence of postoperative aortic regurgitation. Older age and larger valve size were other predictors of reduced postoperative mean gradients.The use of an automatic fastener (Core-Knot) in surgical aortic valve replacement cases reduce aortic cross-clamp time and help eliminate postoperative paravalvular aortic regurgitation.
No takes yet. Share an insight, caveat, or question.
Loberman et al. (2018) conducted a cohort in Surgical aortic valve replacement (n=119). Core-Knot device vs. Manually tied knots was evaluated on Aortic cross-clamp time (minutes) (p=<0.001). The use of the Core-Knot automatic fastener during surgical aortic valve replacement significantly reduced median aortic cross-clamp time compared to manually tied knots (70 vs 84 minutes; P<0.001).