Key result
Cor-Knot automated fasteners significantly reduced cardiopulmonary bypass time in mitral valve surgery compared to manual tying (WMD 110.0; 95% CI 12.3-207.7; P=0.027).
Why the study?
Whether the use of Cor-Knot automated fasteners in heart valve surgery translates to improved patient outcomes remains debatable despite known operative time reductions.
Does automated fastener application reduce operative times and improve safety compared to manual tying in patients undergoing heart valve surgery?
Meta-Analysis (n=810)
Does automated fastener application reduce operative times and improve safety compared to manual tying in patients undergoing heart valve surgery?
Mean Difference: 110 (95% CI 12.3–207.7)
p-value: p=0.027
The use of automated fasteners in heart valve surgery safely reduces operative times, though evidence is lacking that this translates to improved postoperative clinical outcomes.
INTRODUCTION: Cor-Knot automated fastener has been used as an adjunct in heart valve surgery to eliminate the need for manual tying during valve implantation. Although reduced operative time and facilitation for minimally invasive surgery are clear benefits, whether their use translates to improved patient outcome remains debatable. This study aims to review the safety and efficacy of automated fasteners in heart valve surgeries. METHOD: Specific searches were conducted via online medical databases (Pubmed, Embase, Ovid) between 1950 and June 2019. Longitudinal studies were included that provided operative parameters. RESULTS: The initial literature search identified 3773 articles, but only eight met the inclusion criteria and were used for analysis: four studies related to aortic valve replacement (AVR), four related to mitral valve (MV) intervention (total n = 810). The meta-analysis revealed the significantly shorter aortic cross-clamp time in the Cor-knot group compared to manual tying, both in AVR and MV surgeries (P < .05). Cardiopulmonary bypass time was significantly shorter in the Cor-knot group when analyzing studies in MV surgery (weighted mean difference [WMD]: 110.0; 95% confidence interval: 12.3-207.7; P = .027) The use of Cor-Knot did not increase the risk of permanent pacemaker implantation, paravalvular leak, and 30-day mortality. The majority of studies reported no change in the length of intensive unit care and total hospital stay. CONCLUSION: We confirmed that the majority of existing literatures indicated the safety and intraoperative efficacy with automated fastener application. Nevertheless, there is currently no evidence to support automated fastened sutures can translate its intraoperative advantages to improved patient outcome.
No takes yet. Share an insight, caveat, or question.
Salmasi et al. (2019) conducted a meta-analysis in Heart valve surgery (n=810). Cor-Knot automated fastener vs. Manual tying was evaluated on Cardiopulmonary bypass time in mitral valve surgery (WMD 110.0, 95% CI 12.3-207.7, p=0.027). Cor-Knot automated fasteners significantly reduced cardiopulmonary bypass time in mitral valve surgery compared to manual tying (WMD 110.0; 95% CI 12.3-207.7; P=0.027).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: